On-and-off chip cooling of a Coulomb blockade thermometer down to 2.8 mK
arXiv:1708.09491 · doi:10.1063/1.5002565
Abstract
Cooling nanoelectronic devices below 10 mK is a great challenge since thermal conductivities become very small, thus creating a pronounced sensitivity to heat leaks. Here, we overcome these difficulties by using adiabatic demagnetization of \emph{both} the electronic leads \emph{and} the large metallic islands of a Coulomb blockade thermometer. This reduces the external heat leak through the leads and also provides on-chip refrigeration, together cooling the thermometer down to 2.80.1 mK. We present a thermal model which gives a good qualitative account and suggests that the main limitation is heating due to pulse tube vibrations. With better decoupling, temperatures below 1 mK should be within reach, thus opening the door for microkelvin nanoelectronics.
4 pages, 3 color figures
References in corpus (8)
- Signatures of Majorana fermions in hybrid superconductor-semiconductor nanowire devices
- Majorana Fermions and a Topological Phase Transition in Semiconductor-Superconductor Heterostructures
- Magnetic Ordering of Nuclear Spins in an Interacting 2D Electron Gas
- Primary thermometry triad at 6 mK in mesoscopic circuits
- Fractional Quantum Hall Effect at Landau Level Filling nu=4/11
- Observation of Incompressibility at and
- Dry demagnetization cryostat for sub-millikelvin helium experiments: refrigeration and thermometry
- Quantum Hall ferromagnetic states and spin-orbit interactions in the fractional regime