On the "unreasonable" effectiveness of Transport of Intensity imaging and optical deconvolution
arXiv:1708.02746 · doi:10.1364/JOSAA.34.002251
Abstract
The effectiveness of reconstructive imaging using the Homogeneous Transport of Intensity equation may be regarded as "unreasonable", because it has been shown to significantly increase signal-to-noise ratio while preserving spatial resolution, compared to equivalent conventional absorption-based imaging techniques at the same photon fluence. We reconcile this surprising behaviour by analysing the propagation of noise in typical in-line holography experiments. This analysis indicates that novel imaging techniques may be designed which produce high signal-to-noise images at low radiation doses without sacrificing spatial resolution.
References in corpus (11)
- An assessment of the resolution limitation due to radiation-damage in x-ray diffraction microscopy
- Fourier-transform Ghost Imaging with Hard X-rays
- Experimental x-ray ghost imaging
- The physics of Hanbury Brown--Twiss intensity interferometry: from stars to nuclear collisions
- Hanbury Brown and Twiss interferometry at a free-electron laser
- Incoherent Diffractive Imaging via Intensity Correlations of hard X-rays
- On spatial resolution, signal-to-noise and information capacity of linear imaging systems
- Statistical properties of a free-electron laser revealed by the Hanbury Brown and Twiss interferometry
- On noise-resolution uncertainty in quantum field theory
- On the van Cittert - Zernike theorem for intensity correlations and its applications
- CT dose reduction factors in the thousands using X-ray phase contrast
Cited by in corpus (11)
- On Random-Matrix Bases, Ghost Imaging and X-ray Phase Contrast Computational Ghost Imaging
- X-ray Fokker--Planck equation for paraxial imaging
- Single-shot x-ray speckle-based imaging of a single-material object
- On the efficiency of computational imaging with structured illumination
- Boosting spatial resolution by incorporating periodic boundary conditions into single-distance hard-x-ray phase retrieval
- Phase-and-amplitude recovery from a single phase contrast image using partially spatially coherent X-ray radiation
- Tomographic phase and attenuation extraction for a sample composed of unknown materials using X-ray propagation-based phase-contrast imaging
- Characterization of breast tissues in density and effective atomic number basis via spectral X-ray computed tomography
- X-ray ghost tomography: denoising, dose fractionation and mask considerations
- Quantitative Stain Mapping in X-ray Virtual Histology
- Single-exposure elemental differentiation and texture-sensitive phase-retrieval imaging with a neutron counting micro-channel plate detector