Study of cryogenic photomultiplier tubes for the future two-phase cryogenic avalanche detector
arXiv:1705.01250 · doi:10.1088/1748-0221/12/05/C05002
Abstract
We report the results of a characterization study of several types of cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes, 3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch R11410-20 tubes originally designed for operation in liquid Xe. These types of PMT are proposed for installation into the future two-phase cryogenic avalanche detector that is developed in the Laboratory of Cosmology and Particle Physics of the Novosibirsk State University jointly with the Budker Institute of Nuclear Physics. Eight R11065 PMTs and seven R11410-20 tubes were tested and all demonstrated excellent performance in liquid Ar in terms of gain and relative single electron efficiency. All 3-inch PMTs showed a maximal gain in liquid Ar above 5x10^6 and relative single electron efficiency higher than 95%. Compact R6041-506MOD tubes have dynode system different from that of the 3-inch photomultipliers and thus their single electron energy resolution and relative efficiency is much worse than that of 3-inch tubes. From 21 2-inch PMTs only 12 tubes were selected with acceptable, i.e. higher than 75%, relative single electron efficiency and the maximal gain higher than 5x10^6. However, these PMTs are very attractive because they are the only compact type of tubes that can operate in liquid Ar.
arXiv commentSubmitted to the Proceedings of the Instrumentation for Colliding Beam Physics INSTR17 Conference, to be published in JINST
References in corpus (14)
- First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
- Two-Phase Emission Detector for Measuring Coherent Neutrino-Nucleus Scattering
- Advances in Cryogenic Avalanche Detectors
- Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
- Performance of the Hamamatsu R11410 Photomultiplier Tube in cryogenic Xenon Environments
- An Ultra-Low Background PMT for Liquid Xenon Detectors
- Detection of reactor antineutrino coherent scattering off nuclei with a two-phase noble gas detector
- Measurement of the absolute Quantum Efficiency of Hamamatsu model R11410-10 photomultiplier tubes at low temperatures down to liquid xenon boiling point
- Photon emission and atomic collision processes in two-phase argon doped with xenon and nitrogen
- Measurement of the ionization yield of nuclear recoils in liquid argon at 80 and 233 keV
- Two-phase Cryogenic Avalanche Detector with electroluminescence gap operated in argon doped with nitrogen
- Characterization of photo-multiplier tubes for the Cryogenic Avalanche Detector
- Proportional electroluminescence in two-phase argon and its relevance to rare-event experiments
- MPPC versus MRS APD in two-phase Cryogenic Avalanche Detectors
Cited by in corpus (7)
- Revealing neutral bremsstrahlung in two-phase argon electroluminescence
- Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications
- Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap
- Further studies of proportional electroluminescence in two-phase argon
- Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches
- Observation of unusual slow components in electroluminescence signal of two-phase argon detector
- Unraveling the puzzle of slow components in gaseous argon of two-phase detectors for dark matter searches using Thick Gas Electron Multiplier