An in-situ method for measuring the non-linear response of a Fabry-Perot cavity
arXiv:1605.05834 · doi:10.1063/1.4963361
Abstract
High finesse Fabry-Perot(FP) cavity is a very important frequency reference for laser stabiliza- tion, and is widely used for applications such as precision measurement, laser cooling of ions or molecules. But the non-linear response of the piezoelectric ceramic transducer (PZT) in the FP cav- ity limits the performance of the laser stabilization. Measuring and controlling such non-linearity are important. Here we report an in-situ, optical method to characterize this non-linearity by measuring the resonance signals of a dual-frequency laser. The differential measurement makes it insensitive to laser and cavity drifting, and has a very high sensitivity. It can be applied for various applications with PZT, especially in an optical lab.
arXiv comment7 pages, 2 figures
References in corpus (7)
- Advanced LIGO
- An Optical Lattice Clock with Accuracy and Stability at the Level
- Realizing a lattice spin model with polar molecules
- Laser cooling of a diatomic molecule
- Creation of a low-entropy quantum gas of polar molecules in an optical lattice
- Rotational state microwave mixing for laser cooling of complex diatomic molecules
- Optical transfer cavity stabilization using current-modulated injection-locked diode lasers