Polarization leakage in epoch of reionization windows: II. Primary beam model and direction dependent calibration
arXiv:1604.04534 · doi:10.1093/mnras/stw1863
Abstract
Leakage of diffuse polarized emission into Stokes I caused by the polarized primary beam of the instrument might mimic the spectral structure of the 21-cm signal coming from the epoch of reionization (EoR) making their separation difficult. Therefore, understanding polarimetric performance of the antenna is crucial for a successful detection of the EoR signal. Here, we have calculated the accuracy of the nominal model beam of LOFAR in predicting the leakage from Stokes I to Q, U by comparing them with the corresponding leakage of compact sources actually observed in the 3C295 field. We have found that the model beam has errors of less than or equal to 10% on the predicted levels of leakage of ~1% within the field of view, i. e. if the leakage is taken out perfectly using this model the leakage will reduce to of the Stokes I flux. If similar levels of accuracy can be obtained in removing leakage from Stokes Q, U to I, we can say, based on the results of our previous paper, that the removal of this leakage using this beam model would ensure that the leakage is well below the expected EoR signal in almost the whole instrumental k-space of the cylindrical power spectrum. We have also shown here that direction dependent calibration can remove instrumentally polarized compact sources, given an unpolarized sky model, very close to the local noise level.
13 pages, 15 figures, accepted in MNRAS on 26 July 2016
References in corpus (12)
- Post-correlation radio frequency interference classification methods
- Foreground simulations for the LOFAR - Epoch of Reionization Experiment
- The Scale of the Problem : Recovering Images of Reionization with GMCA
- SKALA, a log-periodic array antenna for the SKA-low instrument: design, simulations, tests and system considerations
- Power spectrum extraction for redshifted 21-cm epoch of reionization experiments: the LOFAR case
- The Importance of Wide-field Foreground Removal for 21 cm Cosmology: A Demonstration With Early MWA Epoch of Reionization Observations
- Understanding Instrumental Stokes Leakage in Murchison Widefield Array Polarimetry
- The Hydrogen Epoch of Reionization Array Dish I: Beam Pattern Measurements and Science Implications
- Limits on Foreground Subtraction from Chromatic Beam Effects in Global Redshifted 21 cm Measurements
- Constraining Polarized Foregrounds for EoR Experiments I: 2D Power Spectra from the PAPER-32 Imaging Array
- Beamforming Errors in Murchison Widefield Array Phased Array Antennas and their effects on Epoch of Reionization Science
- Adaptive Weighting in Radio Interferometric Imaging
Cited by in corpus (28)
- The LOFAR Two-metre Sky Survey -- V. Second data release
- Fundamental Physics with the Square Kilometre Array
- Improved upper limits on the 21-cm signal power spectrum of neutral hydrogen at from LOFAR
- Upper limits on the 21-cm Epoch of Reionization power spectrum from one night with LOFAR
- First Results from HERA Phase I: Upper Limits on the Epoch of Reionization 21 cm Power Spectrum
- Improved Constraints on the 21 cm EoR Power Spectrum and the X-Ray Heating of the IGM with HERA Phase I Observations
- The challenges of low-frequency radio polarimetry: lessons from the Murchison Widefield Array
- Calibration and Stokes Imaging with Full Embedded Element Primary Beam Model for the Murchison Widefield Array
- First upper limits on the 21 cm signal power spectrum from cosmic dawn from one night of observations with NenuFAR
- Polarization leakage in epoch of reionization windows: III. Wide-field effects of narrow-field arrays
- Wide-field LOFAR-LBA power-spectra analyses: Impact of calibration, polarization leakage and ionosphere
- Constraining Polarized Foregrounds for EOR Experiments II: Polarization Leakage Simulations in the Avoidance Scheme
- Simulations of Galactic polarized synchrotron emission for Epoch of Reionization observations
- Validation of the HERA Phase I Epoch of Reionization 21 cm Power Spectrum Software Pipeline
- Spectral performance of SKA Log-periodic Antennas I: Mitigating spectral artefacts in SKA1-LOW 21-cm cosmology experiments
- The HERA-19 Commissioning Array: Direction Dependent Effects
- Statistical analysis of the causes of excess variance in the 21 cm signal power spectra obtained with the Low-Frequency Array
- Reliable detection and characterization of low-frequency polarized sources in the LOFAR M51 field
- Calibration Requirements for Epoch of Reionization 21-cm signal observations -- I. Effect of time-correlated gains
- All Sky Modelling Requirements for Bayesian 21 cm Power Spectrum Estimation with BayesEoR
- Degree-Scale Galactic Radio Emission at 122 MHz around the North Celestial Pole with LOFAR-AARTFAAC
- Spectral modelling of Cygnus A between 110 and 250 MHz. Impact on the LOFAR 21-cm signal power spectrum
- Square Kilometre Array Science Data Challenge 3a: foreground removal for an EoR experiment
- Spin-based removal of instrumental systematics in 21cm intensity mapping surveys
- Calibration requirement for Epoch of Reionization 21-cm signal observation -- III. Bias and variance in uGMRT ELAIS-N1 field power spectrum
- The impact of lunar topography on the 21-cm power spectrum for grid-based arrays : Insights for the Dark-ages EXplorer (DEX)
- beamModelTester: software framework for testing radio telescope beams
- An Introduction to Single-Antenna Radio Astronomical Polarimetry