The Si/CdTe semiconductor Compton camera of the ASTRO-H Soft Gamma-ray Detector (SGD)
arXiv:1509.00588 · doi:10.1016/j.nima.2014.05.127
Abstract
The Soft Gamma-ray Detector (SGD) is one of the instrument payloads onboard ASTRO-H, and will cover a wide energy band (60--600 keV) at a background level 10 times better than instruments currently in orbit. The SGD achieves low background by combining a Compton camera scheme with a narrow field-of-view active shield. The Compton camera in the SGD is realized as a hybrid semiconductor detector system which consists of silicon and cadmium telluride (CdTe) sensors. The design of the SGD Compton camera has been finalized and the final prototype, which has the same configuration as the flight model, has been fabricated for performance evaluation. The Compton camera has overall dimensions of 12 cm x 12 cm x 12 cm, consisting of 32 layers of Si pixel sensors and 8 layers of CdTe pixel sensors surrounded by 2 layers of CdTe pixel sensors. The detection efficiency of the Compton camera reaches about 15% and 3% for 100 keV and 511 keV gamma rays, respectively. The pixel pitch of the Si and CdTe sensors is 3.2 mm, and the signals from all 13312 pixels are processed by 208 ASICs developed for the SGD. Good energy resolution is afforded by semiconductor sensors and low noise ASICs, and the obtained energy resolutions with the prototype Si and CdTe pixel sensors are 1.0--2.0 keV (FWHM) at 60 keV and 1.6--2.5 keV (FWHM) at 122 keV, respectively. This results in good background rejection capability due to better constraints on Compton kinematics. Compton camera energy resolutions achieved with the final prototype are 6.3 keV (FWHM) at 356 keV and 10.5 keV (FWHM) at 662 keV, respectively, which satisfy the instrument requirements for the SGD Compton camera (better than 2%). Moreover, a low intrinsic background has been confirmed by the background measurement with the final prototype.
12 pages, 14 figures
References in corpus (13)
- The Burst Alert Telescope (BAT) on the Swift MIDEX Mission
- Recent Progress in CdTe and CdZnTe Detectors
- PAMELA - A Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics
- The AGILE Mission
- In-Orbit Performance of the Hard X-ray Detector on board Suzaku
- The ASTRO-H Mission
- High energy resolution hard X-ray and gamma-ray imagers using CdTe diode devices
- The ASTRO-H X-ray Observatory
- Performance of a Low Noise Front-end ASIC for Si/CdTe Detectors in Compton Gamma-ray Telescope
- Soft Gamma-ray Detector for the ASTRO-H Mission
- Wide band X-ray Imager (WXI) and Soft Gamma-ray Detector (SGD) for the NeXT Mission
- Design and Performance of the Soft Gamma-ray Detector for the NeXT mission
- Gamma-ray Polarimetry
Cited by in corpus (18)
- The ASTRO-H X-ray Astronomy Satellite
- FOXSI-2: Upgrades of the Focusing Optics X-ray Solar Imager for its Second Flight
- Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
- Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector
- The first demonstration of the concept of "narrow-FOV Si/CdTe semiconductor Compton camera"
- A compact imaging system with a CdTe double-sided strip detector for non-destructive analysis using negative muonic X-rays
- Optimization of Timepix3-based conventional Compton camera using electron track algorithm
- Tomographic Imaging by a Si/CdTe Compton Camera for In-111 and I-131 Radionuclides
- Fine-pitch CdTe detector for hard X-ray imaging and spectroscopy of the Sun with the FOXSI rocket experiment
- 2-mm-Thick Large-Area CdTe Double-sided Strip Detectors for High-Resolution Spectroscopic Imaging of X-ray and Gamma-ray with Depth-Of-Interaction Sensing
- Study of the Polarimetric Performance of a Si/CdTe Semiconductor Compton Camera for the Hitomi Satellite
- An application of a Si/CdTe Compton camera for the polarization measurement of hard x-rays from highly charged heavy ions
- Imaging and Spectral Performance of a 60 μm Pitch CdTe Double-Sided Strip Detector
- Demonstration of nuclear gamma-ray polarimetry based on a multi-layer CdTe Compton Camera
- Wide-gap CdTe Strip Detectors for High-Resolution Imaging in Hard X-rays
- Time projection chambers for gamma-ray astronomy
- Imaging and Spectral Performance of a Wide-gap CdTe Double-Sided Strip Detector
- Performance study of a directional fast neutron detection system based on TPC and plastic scintillation detectors