Abstract
The study of nuclei farther from the valley of -stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference. TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of Cs. Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.
arXiv comment14 Pages, 5 Figures. Preprint to be submitted to the Proceedings of the 2015EMIS Conference in NIMB
References in corpus (17)
- Precision Atomic Physics Techniques for Nuclear Physics with Radioactive Beams
- Limits on the neutrino mass from neutrinoless double- decay
- First Penning-trap mass measurement in the millisecond half-life range: the exotic halo nucleus 11Li
- TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance
- First Results from the CARIBU Facility: Mass Measurements on the r-Process Path
- First Use of High Charge States for Mass Measurements of Short-lived Nuclides in a Penning Trap
- Verifying the accuracy of the TITAN Penning-trap mass spectrometer
- Isomeric states close to doubly magic Sn studied with JYFLTRAP
- A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials
- Penning-trap mass spectrometry of highly charged, neutron-rich Rb and Sr isotopes in the vicinity of
- Highly charged ions in Penning traps, a new tool for resolving low lying isomeric states
- Extinction of the N=20 neutron-shell closure for 32Mg examined by direct mass measurements
- Penning-Trap Mass Measurements of the Neutron-Rich K and Ca Isotopes: Resurgence of the N = 28 Shell Strength
- The TITAN in-trap decay spectroscopy facility at TRIUMF
- First direct determination of the superallowed -decay -value for O
- Low-Background In-Trap Decay Spectroscopy with TITAN at TRIUMF
- Sensitivity Increases for the TITAN Decay Spectroscopy Program