How to confirm and exclude different models of material properties in the Casimir effect
arXiv:1411.4548 · doi:10.1088/0953-8984/27/21/214013
Abstract
We formulate a method allowing to confirm or exclude the alternative models of material properties at some definite confidence level in experiments on measuring the Casimir force. The method is based on the consideration of differences between the theoretical and mean measured quantities and the confidence intervals for these differences found at sufficiently high or low confidence probabilities. The developed method is applied to the data of four recent experiments on measuring the gradient of the Casimir force by means of a dynamic atomic force microscope. It is shown that in experiments with Au-Au and Ni-Ni test bodies, where the Drude model approach is excluded at a 95% confidence level, the plasma model approach agrees with the data at higher than 90% confidence. In experiments using an Au sphere interacting with either a Ni plate or a graphene-coated substrate the measurement data agree with the common prediction of the Drude and plasma model approaches and theory using the polarization tensor at 90% and 80% confidence levels, respectively.
14 pages, 9 figures, invited contribution to the special issue on Casimir Forces to be published in J. Phys.: Condens. Matt
References in corpus (15)
- The electronic properties of graphene
- Measurement of the Temperature Dependence of the Casimir-Polder Force
- Novel constraints on light elementary particles and extra-dimensional physics from the Casimir effect
- Control of the Casimir force by the modification of dielectric properties with light
- Demonstration of optically modulated dispersion forces
- Demonstration of the Casimir force between ferromagnetic surfaces of a Ni-coated sphere and a Ni-coated plate
- Conductivity of dielectric and thermal atom-wall interaction
- Theory of the Casimir interaction for graphene-coated substrates using the polarization tensor and comparison with experiment
- Kramers-Kronig relations for plasma-like permittivities and the Casimir force
- Control of the Casimir Force Using Semiconductor Test Bodies
- Kelvin probe force microscopy of metallic surfaces used in Casimir force measurements
- Observability of thermal effects in the Casimir interaction from graphene-coated substrates
- Magnetic materials and the problem of thermal Casimir force
- Derivation of the Lifshitz-Matsubara sum formula for the Casimir pressure between metallic plane mirrors
- The locality of surface interactions on colloidal probes
Cited by in corpus (6)
- Precision measurements of the gradient of the Casimir force between ultra clean metallic surfaces at larger separations
- Casimir free energy and pressure for magnetic metal films
- No-slip boundary conditions for electron hydrodynamics and the thermal Casimir pressure
- Universal experimental test for the role of free charge carriers in thermal Casimir effect within a micrometer separation range
- Nonperturbative theory of atom-surface interaction: Corrections at short separations
- Attractive and repulsive fluctuation-induced pressure in peptide films deposited on semiconductor substrates