Stabilizing a Fabry-Perot etalon to 3 cm/s for spectrograph calibration
arXiv:1404.0004 · doi:10.1086/682879
Abstract
We present a method of frequency stabilizing a broadband etalon that can serve as a high-precision wavelength calibrator for an Echelle spectrograph. Using a laser to probe the Doppler-free saturated absorption of the rubidium D2 line, we stabilize one etalon transmission peak directly to the rubidium frequency. The rubidium transition is an established frequency standard and has been used to lock lasers to fractional stabilities of , a level of accuracy far exceeding the demands of radial velocity (RV) searches for exoplanets. We describe a simple setup designed specifically for use at an observatory and demonstrate that we can stabilize the etalon peak to a relative precision of ; this is equivalent to 3 cm/s RV precision.
arXiv comment9 pages, 6 figures. Submitted to PASP
References in corpus (14)
- Optical frequency comb generation from a monolithic microresonator
- A laser frequency comb that enables radial velocity measurements with a precision of 1 cm s
- An extrasolar planetary system with three Neptune-mass planets
- A new list of thorium and argon spectral lines in the visible
- The Habitable-Zone Planet Finder: A Stabilized Fiber-Fed NIR Spectrograph for the Hobby-Eberly Telescope
- Demonstration of On-Sky Calibration of Astronomical Spectra using a 25 GHz near-IR Laser Frequency Comb
- Selection of ThAr lines for wavelength calibration of echelle spectra and implications for variations in the fine-structure constant
- Development of Fiber Fabry-Perot Interferometers as Stable Near-infrared Calibration Sources for High Resolution Spectrographs
- An Ultra-High Stability, Low-Noise Laser Current Driver with Digital Control
- On The Use of Absorption Cells as a Wavelength Reference for Precision Radial Velocity Measurements in the Near Infrared
- Mode-hop-free tuning over 135 GHz of external cavity diode lasers without anti-reflection coating
- Development of a New, Precise Near-infrared Doppler Wavelength Reference: A Fiber Fabry-Perot Interferometer
- The Pathfinder Testbed: Exploring Techniques for Achieving Precision Radial Velocities in the Near-Infrared
- Precision near-infrared radial velocity instrumentation I: Absorption Gas Cells
Cited by in corpus (15)
- State of the Field: Extreme Precision Radial Velocities
- Instrumentation for the detection and characterization of exoplanets
- Efficient injection from large telescopes into single-mode fibres: Enabling the era of ultra-precision astronomy
- Enhancing stellar spectroscopy with extreme adaptive optics and photonics
- 2023 Astrophotonics Roadmap: pathways to realizing multi-functional integrated astrophotonic instruments
- Demonstration of an efficient, photonic-based astronomical spectrograph on an 8-m telescope
- A new infrared Fabry-Pérot-based radial-velocity-reference module for the SPIRou radial-velocity spectrograph
- New wavelength calibration of the HARPS spectrograph
- Rubidium-traced white-light etalon calibrator for radial velocity measurements at the cm/s level
- Frequency stability characterization of a broadband fiber Fabry-Perot interferometer
- Forecasting cosmic acceleration measurements using the Lyman- forest
- A Radial Velocity Error Budget for Single-mode Fiber Doppler Spectrographs
- Effect of near-field distribution on transmission characteristics of fiber-fed Fabry-Perot etalons
- Performance estimates for spectrographs using photonic reformatters
- Using birefringent elements and imaging Michelsons for calibration of high precision planet finding spectrographs