Development of High Precision Timing Counter Based on Plastic Scintillator with SiPM Readout
arXiv:1402.1404 · doi:10.1109/TNS.2014.2347576
Abstract
High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have studied counter sizes up to mm^3 with series connection of multiple SiPMs to increase the sensitive area and thus achieve better time resolution. A readout scheme with analog shaping and digital waveform analysis is optimized to achieve the highest time resolution. The timing performance is measured using electrons from a Sr-90 radioactive source, comparing different scintillators, counter dimensions, and types of near-ultraviolet sensitive SiPMs. As a result, a resolution of ps at 1 MeV energy deposition is obtained for counter size mm^3 with three SiPMs ( mm^2 each) at each end of the scintillator. The time resolution improves with the number of photons detected by the SiPMs. The SiPMs from Hamamatsu Photonics give the best time resolution because of their high photon detection efficiency in the near-ultraviolet region. Further improvement is possible by increasing the number of SiPMs attached to the scintillator.
11 pages, 17 figures, accepted by IEEE Trans. Nucl. Sci
References in corpus (1)
Cited by in corpus (14)
- The design of the MEG II experiment
- The new versatile general purpose surface-muon instrument (GPS) based on silicon photomultipliers for SR measurements on a continuous-wave beam
- Perspective on the muon-spin rotation/relaxation under hydrostatic pressure
- Application of large area SiPMs for the readout of a plastic scintillator based timing detector
- Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs
- Barrel time-of-flight detector for the PANDA experiment at FAIR
- Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider
- A beam-beam monitoring detector for the MPD experiment at NICA
- The MEGII detector
- Time resolution of BC422 plastic scintillator read out by a SiPM
- The laser-based time calibration system for the MEG II pixelated Timing Counter
- Front-end Electronics and Optimal Ganging Schemes for Single Photon Detection with Large Arrays of SiPMs in Liquid Argon
- Characterization of a silicon photo-multiplier array with summing board as a photo-multiplier tube replacement in organic scintillator assemblies
- A fast plastic scintillator for low intensity proton beam monitoring