Krypton assay in xenon at the ppq level using a gas chromatographic system and mass spectrometer
arXiv:1308.4806 · doi:10.1140/epjc/s10052-014-2746-1
Abstract
We have developed a new method to measure krypton traces in xenon at unprecedented low concentrations. This is a mandatory task for many near-future low-background particle physics detectors. Our system separates krypton from xenon using cryogenic gas chromatography. The amount of krypton is then quantified using a mass spectrometer. We demonstrate that the system has achieved a detection limit of 8 ppq (parts per quadrillion) and present results of distilled xenon with krypton concentrations below 1 ppt.
7 pages, 4 figures
References in corpus (1)
Cited by in corpus (29)
- Dark Matter Search Results from a One TonneYear Exposure of XENON1T
- First Dark Matter Search Results from the XENON1T Experiment
- Excess Electronic Recoil Events in XENON1T
- Physics reach of the XENON1T dark matter experiment
- Dark matter direct-detection experiments
- DARWIN: towards the ultimate dark matter detector
- Search for New Physics in Electronic Recoil Data from XENONnT
- The XENON1T Dark Matter Experiment
- Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment
- A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- XENON100 Dark Matter Results from a Combination of 477 Live Days
- XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference
- The XENONnT Dark Matter Experiment
- Removing krypton from xenon by cryogenic distillation to the ppq level
- Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data
- Search for Event Rate Modulation in XENON100 Electronic Recoil Data
- WIMP Dark Matter Direct-Detection Searches in Noble Gases
- Double-Weak Decays of Xe and Xe in the XENON1T and XENONnT Experiments
- WIMP Dark Matter Search using a 3.1 Tonne-Year Exposure of the XENONnT Experiment
- Chromatographic separation of radioactive noble gases from xenon
- Direct Detection of Dark Matter -- APPEC Committee Report
- Prospects for dark matter detection with inelastic transitions of xenon
- Intrinsic backgrounds from Rn and Kr in the XENON100 experiment
- An atom trap trace analysis system for measuring krypton contamination in xenon dark matter detectors
- The XLZD Design Book: Towards the Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
- Optical Excitation and Trapping of Kr
- A novel Kr tracer method for characterizing xenon gas and cryogenic distillation systems
- New method of 85Kr reduction in a noble gas based low-background detector
- Improved and automated krypton assay for low-background xenon detectors with Auto-RGMS