paper

High accuracy correction of blackbody radiation shift in an optical lattice clock

arXiv:1208.2848 · doi:10.1103/PhysRevLett.109.263004

Abstract

We have determined the frequency shift that blackbody radiation is inducing on the S -- P clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to . Now the uncertainty associated to the black body radiation shift correction translates to relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

9 pages, 4 figures, including appendix with supplementary text. Version 2 with adjusted value of differential static polarizability due to field plate separation measurement

References in corpus (6)

Cited by in corpus (27)