The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
arXiv:1204.0978 · doi:10.1051/0004-6361/201116576
Abstract
Reliable timing calibration is essential for the accurate comparison of XMM-Newton light curves with those from other observatories, to ultimately use them to derive precise physical quantities. The XMM-Newton timing calibration is based on pulsar analysis. However, as pulsars show both timing noise and glitches, it is essential to monitor these calibration sources regularly. To this end, the XMM-Newton observatory performs observations twice a year of the Crab pulsar to monitor the absolute timing accuracy of the EPIC-pn camera in the fast Timing and Burst modes. We present the results of this monitoring campaign, comparing XMM-Newton data from the Crab pulsar (PSR B0531+21) with radio measurements. In addition, we use five pulsars (PSR J0537-69, PSR B0540-69, PSR B0833-45, PSR B1509-58 and PSR B1055-52) with periods ranging from 16 ms to 197 ms to verify the relative timing accuracy. We analysed 38 XMM-Newton observations (0.2-12.0 keV) of the Crab taken over the first ten years of the mission and 13 observations from the five complementary pulsars. All the data were processed with the SAS, the XMM-Newton Scientific Analysis Software, version 9.0. Epoch folding techniques coupled with χ^{2} tests were used to derive relative timing accuracies. The absolute timing accuracy was determined using the Crab data and comparing the time shift between the main X-ray and radio peaks in the phase folded light curves. The relative timing accuracy of XMM-Newton is found to be better than 10^{-8}. The strongest X-ray pulse peak precedes the corresponding radio peak by 306\pm9 \mus, which is in agreement with other high energy observatories such as Chandra, INTEGRAL and RXTE. The derived absolute timing accuracy from our analysis is \pm48 \mus.
16 pages, 9 figures. Accepted for publication on A&A
References in corpus (6)
Cited by in corpus (18)
- Timing Observations of PSR J1023+0038 During a Low-Mass X-ray Binary State
- Pulsating in unison at optical and X-ray energies: simultaneous high-time resolution observations of the transitional millisecond pulsar PSR J1023+0038
- Review of X-ray pulsar spacecraft autonomous navigation
- PSR J0357+3205: the tail of the turtle
- A broadband X-ray study of the Geminga pulsar with NuSTAR and XMM-Newton
- The variable spin-down rate of the transient magnetar XTE J1810--197
- Precise optical timing of PSR J1023+0038, the first millisecond pulsar detected with Aqueye+ in Asiago
- Enhanced X-ray Emission Coinciding with Giant Radio Pulses from the Crab Pulsar
- High-Energy Emission of the First Millisecond Pulsar
- Investigating the origin of optical and X-ray pulsations of the transitional millisecond pulsar PSR J1023+0038
- The 11 years of low-activity of the magnetar XTE J1810-197
- Test of Weak Equivalence Principle with the multi-band timing of the Crab Pulsar
- Multiwavelength observations of PSR J2021+4026 across a mode change reveal a phase shift in its X-ray emission
- RXTE/HEXTE Analysis of the Crab Pulsar Glitch of July 2000
- Fast X-ray/IR observations of the black hole transient Swift~J1753.5--0127: from an IR lead to a very long jet lag
- Long Term Study of the Double Pulsar J0737-3039 with XMM-Newton: pulsar timing
- A simple, flexible method for timing cross-calibration of space missions
- Pulse profile variations in the accreting X-ray pulsar Vela X-1