Absolute Timing of the Crab Pulsar with RXTE
arXiv:astro-ph/0403187 · doi:10.1086/420842
Abstract
We have monitored the phase of the main X-ray pulse of the Crab pulsar with the Rossi X-ray Timing Explorer (RXTE) for almost eight years, since the start of the mission in January 1996. The absolute time of RXTE's clock is sufficiently accurate to allow this phase to be compared directly with the radio profile. Our monitoring observations of the pulsar took place bi-weekly (during the periods when it was at least 30 degrees from the Sun) and we correlated the data with radio timing ephemerides derived from observations made at Jodrell Bank. We have determined the phase of the X-ray main pulse for each observation with a typical error in the individual data points of 50 us. The total ensemble is consistent with a phase that is constant over the monitoring period, with the X-ray pulse leading the radio pulse by 0.0102+/-0.0012 period in phase, or 344+/-40 us in time. The error estimate is dominated by a systematic error of 40 us in the radio data, arising from uncertainties in the variable amount of pulse delay due to interstellar scattering and instrumental calibration. The statistical error is 0.00015 period, or 5 us. The separation of the main pulse and interpulse appears to be unchanging at time scales of a year or less, with an average value of 0.4001+/-0.0002 period. There is no apparent variation in these values with energy over the 2-30 keV range. The lag between the radio and X-ray pulses may be constant in phase (rotational) or constant in time (linear pathlength). We are not (yet) able to distinguish between these two interpretations.
arXiv comment11 pages, 2 figures
References in corpus (6)
- -Ray Pulsars: Emission Zones and Viewing Geometries
- Enhanced Optical Emission During Crab Giant Radio Pulses
- Observations of a Series of Six Recent Glitches in the Crab Pulsar
- RXTE Absolute Timing Results for the Pulsars B1821-24 and B1509-58
- Phase-resolved Crab Studies with a Cryogenic TES Spectrophotometer
- Absolute timing with IBIS, SPI and JEM-X aboard INTEGRAL
Cited by in corpus (51)
- In-Orbit Performance of the Hard X-ray Detector on board Suzaku
- Fermi Large Area Telescope Observations of the Crab Pulsar and Nebula
- Discovery of luminous pulsed hard X-ray emission from anomalous X-ray pulsars 1RXS J1708-4009, 4U 0142+61 and 1E 2259+586 by INTEGRAL and RXTE
- When A Standard Candle Flickers
- In-Orbit Performance of MAXI Gas Slit Camera (GSC) on ISS
- Intermittent millisecond X-ray pulsations from the neutron-star X-ray transient SAX J1748.9-2021 in the globular cluster NGC 6440
- Optical polarisation of the Crab pulsar: precision measurements and comparison to the radio emission
- The magnetic field strengths of accreting millisecond pulsars
- High-energy characteristics of the schizophrenic pulsar PSR J1846-0258 in Kes 75
- Updating the orbital ephemeris of Her X-1; rate of decay and eccentricity of the orbit
- X-ray and Radio Timing of the Pulsar in 3C 58
- Interplanetary spacecraft navigation using pulsars
- Fermi/GBM Observations of SGR J0501+4516 Bursts
- X-ray Phase-Resolved Spectroscopy of PSRs B0531+21, B1509-58, and B0540-69 with RXTE
- Phase-coherent timing of the accreting millisecond pulsar SAX J1748.9-2021
- Simultaneous Absolute Timing of the Crab Pulsar at Radio and Optical Wavelengths
- In Orbit Timing Calibration of the Hard X-Ray Detector on Board Suzaku
- Absolute timing of the Crab pulsar with the INTEGRAL/SPI telescope
- INTEGRAL observations of the Crab pulsar
- The optical to gamma-ray emission of the Crab pulsar: a multicomponent model
- The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
- Coherence of burst oscillations and accretion-powered pulsations in the accreting millisecond pulsar XTE J1814-338
- Spectral Variation of the Hard X-ray Emission from the Crab Nebula with the Suzaku Hard X-ray Detector
- Enhanced X-ray Emission Coinciding with Giant Radio Pulses from the Crab Pulsar
- The Crab Nebula's Dynamical Age as Measured from its Northern Filamentary Jet
- Evolution of the X-ray Profile of the Crab Pulsar
- Aqueye optical observations of the Crab Nebula pulsar
- Correlation of Chandra photons with the radio giant pulses from the Crab pulsar
- In-orbit timing calibration of the Insight-Hard X-ray Modulation Telescope
- Anomalous Low States and Long Term Variability in the Black Hole Binary LMC X-3
- Test of Weak Equivalence Principle with the multi-band timing of the Crab Pulsar
- Timing accuracy of the Swift X-Ray Telescope in WT mode
- Insight-HXMT observations of the Crab pulsar
- Pulse profile stability of the Crab pulsar
- Discovery of 1-5 Hz flaring at high luminosity in SAX J1808.4-3658
- Testing the Weak Equivalence Principle using Optical and Near-Infrared Crab Pulses
- The Crab pulsar seen with Aqueye at Asiago Cima Ekar Observatory
- Coherent timing of the accreting millisecond pulsar NGC 6440 X-2
- What brakes the Crab pulsar?
- NICER observations of the Crab pulsar glitch of 2017 November
- A non-glitch speed-up event in the Crab Pulsar
- RXTE/HEXTE Analysis of the Crab Pulsar Glitch of July 2000
- Timing Offset Calibration of CZTI instrument aboard ASTROSAT
- Pulsar Navigation in the Solar System
- Study of the High Energy Gamma-ray Emission from the Crab Pulsar with the MAGIC telescope and Fermi-LAT
- Phase Evolution of the Crab Pulsar between Radio and X-ray
- A simple, flexible method for timing cross-calibration of space missions
- Absolute Time Calibration of LAXPC aboard AstroSat
- Simulated Gamma-Ray Pulse Profile of the Crab Pulsar with the Cherenkov Telescope Array
- CubeSats Reach the Millisecond X-Ray Domain: Crab Pulsar Timing with SpIRIT/HERMES
- One-week optical observations of pulsed emission from the Crab pulsar with IMONY on the 3.8 m Seimei telescope