High resolution spatial and timing observations of millisecond pulsar PSR J0218+4232 with Chandra
arXiv:astro-ph/0206081 · doi:10.1086/342220
Abstract
We report on high-resolution spatial and timing results for binary millisecond pulsar PSR J0218+4232 obtained with the Chandra HRC-I and HRC-S in imaging mode. We found no indications for extended emission at 1 arcsec scales. With the HRC-S observation we obtained a 0.08-10 keV pulse profile with high statistics which could be compared in absolute time with the pulse profiles at radio-frequencies and at high-energy gamma-rays. The two X-ray pulses at aligned with 2 of the 3 radio-pulses, and with the 2 gamma-ray pulses.
arXiv comment8 pages, 4 figures, 1 table, Accepted for publication in ApJ Part-1
References in corpus (7)
- Gamma Ray Pulsars: Emission from Extended Polar Cap Cascades
- Full polar cap cascade scenario: -ray and X-ray luminosities from spin-powered pulsars
- Coherently Dedispersed Polarimetry of Millisecond Pulsars
- Detection of an X-ray Pulsar Wind Nebula and Tail in SNR N157B
- Spectral features in gamma-rays expected from millisecond pulsars
- A Systematic Search for Short-term Variability of EGRET Sources
- Rotation as a source of asymmetry in the double-peak lightcurves of the bright EGRET pulsars
Cited by in corpus (31)
- Variability of EGRET Gamma-Ray Sources
- Pulsar Timing for the Fermi Gamma-ray Space Telescope
- The soft gamma-ray pulsar population: an high-energy overview
- Pulsed Gamma Rays from the Original Millisecond and Black Widow Pulsars: a case for Caustic Radio Emission?
- Gamma ray astrophysics: the EGRET results
- Gamma Ray Pulsars: Multiwavelength Observations
- Green Bank Telescope Studies of Giant Pulses from Millisecond Pulsars
- A Search for Giant Pulses from Millisecond Pulsars
- Six millisecond pulsars detected by the Fermi Large Area Telescope and the radio/gamma-ray connection of millisecond pulsars
- Studying Millisecond Pulsars in X-rays
- High-Resolution Timing Observations of Spin-Powered Pulsars with the AGILE Gamma-Ray Telescope
- XMM-Newton spectral and timing observations of the millisecond pulsar PSR J0218+4232
- BeppoSAX observation of PSR B1937+21
- XMM-Newton spectral and timing analysis of the faint millisecond pulsars PSR J0751+1807 and PSR J1012+5307
- Deep Chandra observations of TeV binaries II: LS 5039
- High-Precision X-ray Timing of Three Millisecond Pulsars with NICER: Stability Estimates and Comparison with Radio
- The relative and absolute timing accuracy of the EPIC-pn camera on XMM-Newton, from X-ray pulsations of the Crab and other pulsars
- Chandra and RXTE studies of the X-ray/gamma-ray millisecond pulsar PSR J0218+4232
- X-rays from Radio Millisecond Pulsars: Comptonized Thermal Radiation
- NuSTAR Hard X-ray Observations of the Energetic Millisecond Pulsars PSR B1821-24, PSR B1937+21, and PSR J0218+4232
- Pulsed X-ray Emission from Pulsar A in the Double Pulsar System J0737-3039
- Very Long Baseline Interferometry Measured Proper Motion and Parallax of the -ray Millisecond Pulsar PSR J0218+4232
- High-Energy Emission of the First Millisecond Pulsar
- XMM-Newton and ESO observations of the two unidentified gamma-ray sources 3EG J0616-3310 and 3EG J1249-8330
- Death Line of Gamma-ray Pulsars with Outer Gaps
- A New 626 s Periodic X-ray Source in the Direction of the Galactic Center
- Unidentified gamma-ray sources off the Galactic plane as low-mass microquasars?
- Spectral constraints on unidentified EGRET gamma-ray sources from COMPTEL MeV observations
- Search for Very High-Energy Emission from the millisecond pulsar PSR J0218+4232
- BeppoSAX observations of rotation-powered pulsars
- Pulsar current sheet Cerenkov radiation