Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector
arXiv:1202.3558 · doi:10.1103/PhysRevLett.108.141101
Abstract
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of at 165\,Hz.
Accepted for publication in Physical Review Letters, 5 pages, 2 figures