Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector
arXiv:1202.3558 · doi:10.1103/PhysRevLett.108.141101
Abstract
The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of at 165\,Hz.
arXiv commentAccepted for publication in Physical Review Letters, 5 pages, 2 figures
References in corpus (10)
- Thermodynamical fluctuations and photo-thermal shot noise in gravitational wave antennae
- Thermoelastic effects at low temperatures and quantum limits in displacement measurements
- Thermal noise in half infinite mirrors with non-uniform loss: a slab of excess loss in a half infinite mirror
- Measurement of the mechanical loss of a cooled reflective coating for gravitational wave detection
- Thermal lensing in cryogenic sapphire substrates
- Mechanical quality factor of a sapphire fiber at cryogenic temperatures
- Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope
- Thermal-noise-limited underground interferometer CLIO
- Current status of the CLIO project
- Thermoelastic-damping noise from sapphire mirrors in a fundamental-noise-limited interferometer
Cited by in corpus (10)
- Detector configuration of KAGRA - the Japanese cryogenic gravitational-wave detector
- KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
- Macroscopic Quantum Mechanics in a Classical Spacetime
- Construction of KAGRA: an Underground Gravitational Wave Observatory
- Field Fluctuations in a One-Dimensional Cavity with a Mobile Wall
- Particle swarm optimization of the sensitivity of a cryogenic gravitational wave detector
- High Performance Heat Conductor with Small Spring Constant for Cryogenic Applications
- Status of advanced ground-based laser interferometers for gravitational-wave detection
- Rapid alerts for following up gravitational wave event candidates
- Upper Limit to the Transverse to Longitudinal Motion Coupling of a Waveguide Mirror