Millimeter-wave bolometer array receiver for the Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument
arXiv:1008.0342 · doi:10.1063/1.3637460
Abstract
The Atacama pathfinder experiment Sunyaev-Zel'dovich (APEX-SZ) instrument is a millimeter-wave cryogenic receiver designed to observe galaxy clusters via the Sunyaev-Zel'dovich effect from the 12 m APEX telescope on the Atacama plateau in Chile. The receiver contains a focal plane of 280 superconducting transition-edge sensor (TES) bolometers instrumented with a frequency-domain multiplexed readout system. The bolometers are cooled to 280 mK via a three-stage helium sorption refrigerator and a mechanical pulse-tube cooler. Three warm mirrors, two 4 K lenses, and a horn array couple the TES bolometers to the telescope. APEX-SZ observes in a single frequency band at 150 GHz with 1' angular resolution and a 22' field-of-view, all well suited for cluster mapping. The APEX-SZ receiver has played a key role in the introduction of several new technologies including TES bolometers, the frequency-domain multiplexed readout, and the use of a pulse-tube cooler with bolometers. As a result of these new technologies, the instrument has a higher instantaneous sensitivity and covers a larger field-of-view than earlier generations of Sunyaev-Zel'dovich instruments. The TES bolometers have a median sensitivity of 890 uKcmb-sqrt(s) (NEy of 3.5e-4 sqrt(s)). We have also demonstrated upgraded detectors with improved sensitivity of 530 uKcmb-sqrt(s) (NEy of 2.2e-4 sqrt(s)). Since its commissioning in April 2007, APEX-SZ has been used to map 48 clusters. We describe the design of the receiver and its performance when installed on the APEX telescope.
27 pages, 20 figures, prepared with revtex 4.1
References in corpus (11)
- High resolution CMB power spectrum from the complete ACBAR data set
- The Large APEX Bolometer Camera LABOCA
- The Atacama Cosmology Telescope: The Receiver and Instrumentation
- The build-up of the colour-magnitude relation in galaxy clusters since z~0.8
- The AzTEC mm-Wavelength Camera
- The Atacama Cosmology Telescope: Physical Properties and Purity of a Galaxy Cluster Sample Selected via the Sunyaev-Zel'dovich Effect
- The Magnetothermal Instability in the Intracluster Medium
- Metal enrichment of the intra-cluster medium over a Hubble time for merging and relaxed galaxy clusters
- Multi-frequency imaging of the galaxy cluster Abell 2163 using the Sunyaev-Zel'dovich Effect
- Digital Frequency Domain Multiplexer for mm-Wavelength Telescopes
- Sunyaev-Zel'dovich Effect Observations of the Bullet Cluster (1E 0657-56) with APEX-SZ
Cited by in corpus (12)
- A dual-band millimeter-wave kinetic inductance camera for the IRAM 30-meter telescope
- Frequency Multiplexed SQUID Readout of Large Bolometer Arrays for Cosmic Microwave Background Measurements
- Improved Performance of TES Bolometers using Digital Feedback
- Horn-Coupled, Commercially-Fabricated Aluminum Lumped-Element Kinetic Inductance Detectors for Millimeter Wavelengths
- Non-parametric deprojection of NIKA SZ observations: Pressure distribution in the Planck-discovered cluster PSZ1 G045.85+57.71
- Weak-lensing mass calibration of the Sunyaev-Zel'dovich effect using APEX-SZ galaxy clusters
- The EBEX Balloon Borne Experiment - Detectors and Readout
- Weak lensing measurements of the APEX-SZ galaxy cluster sample
- Galaxy cluster scaling relations measured with APEX-SZ
- CONCERTO at APEX: installation and technical commissioning
- The Simons Observatory: Design and Measured Performance of a Carbon Fiber Strut for a Cryogenic Truss
- Cryogenic sensor enabling broad-band and traceable power measurements