Coherent Dual Comb Spectroscopy at High Signal to Noise
arXiv:1001.3865 · doi:10.1103/PhysRevA.82.043817
Abstract
Two frequency combs can be used to measure the full complex response of a sample in a configuration which can be alternatively viewed as the equivalent of a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual comb spectrometer retains the frequency accuracy and resolution inherent to the comb sources. We discuss, in detail, the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the first overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) is 2,500 for both the fractional absorption and the phase, with a peak SNR of 4,000 corresponding to a fractional absorption sensitivity of 0.025% and phase sensitivity of 250 microradians. As the spectral coverage of combs expands, this dual-comb spectroscopy could provide high frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions.
18 pages, 8 figures updated references, updated to match publication version
References in corpus (8)
- Coherent, multi-heterodyne spectroscopy using stabilized optical frequency combs
- Cavity-enhanced dual-comb spectroscopy
- Phase-stabilized, 1.5-W frequency comb at 2.8 to 4.8 micron
- Cavity Enhanced Optical Vernier Spectroscopy, Broad Band, High Resolution, High Sensitivity
- Ultra low frequency noise laser by locking to an optical fiber delay line
- Cavity-enhanced direct frequency comb spectroscopy
- Sensitive multiplex spectroscopy in the molecular fingerprint 2.4 m region with a Cr^{2+}:ZnSe femtosecond laser
- Femtosecond laser Fourier transform absorption spectroscopy
Cited by in corpus (42)
- On-chip dual comb source for spectroscopy
- Adaptive real-time dual-comb spectroscopy
- High Coherence Mid-Infrared Dual Comb Spectroscopy Spanning 2.6 to 5.2 microns
- Mid-infrared frequency comb generation with silicon nitride nano-photonic waveguides
- Applications of integrated optical microcombs
- Mid-Infrared Frequency Comb Fourier Transform Spectrometer
- Picometer-resolution dual-comb spectroscopy with a free-running fibre laser
- Spectroscopy of the Methane ν3 Band with an Accurate Mid-Infrared Coherent Dual- Comb Spectrometer
- Accurate frequency referencing for fieldable dual-comb spectroscopy
- Baseline-free Quantitative Absorption Spectroscopy Based on Cepstral Analysis
- Coherent cavity-enhanced dual-comb spectroscopy
- Ultrafast electrooptic dual-comb interferometry
- Dual-optical-comb spectroscopic ellipsometry
- Nanophotonic supercontinuum based mid-infrared dual-comb spectroscopy
- Broadband Dual-Comb Spectroscopy in the Spectral Fingerprint Region
- Broadband Dual Frequency Comb Spectroscopy in a Rapid Compression Machine
- On-chip Dual-comb based on Quantum Cascade Laser Frequency Combs
- Electro-optic dual-comb interferometry over 40-nm bandwidth
- Coherently averaged dual-comb spectroscopy with a low-noise and high-power free-running gigahertz dual-comb laser
- Unidirectional, dual-comb lasing under multiple pulse formation mechanisms in a passively mode-locked fiber ring laser
- 11-μs Time-resolved, Continuous Dual-Comb Spectroscopy with Spectrally Filtered Mode-locked Frequency Combs
- Simple Single-Section Diode Frequency Combs
- High-power, hybrid Er:fiber/Tm:fiber frequency comb source in the 2 μm wavelength region
- Fully Stabilized Mid-Infrared Frequency Comb for High-Precision Molecular Spectroscopy
- Multiheterodyne spectroscopy using interband cascade lasers
- Cepstral Analysis for Baseline-Insensitive Absorption Spectroscopy Using Light Sources with Pronounced Intensity Variations
- Ultra-Broadband Microwave Frequency-Comb Generation in Superconducting Resonators
- Mid-Infrared Cross-Comb Spectroscopy
- 1 GHz dual-comb spectrometer for fast and broadband measurements
- Tunable dual-comb spectrometer for mid-infrared trace gas analysis from 3 to 4.7 μm
- Triggerless data acquisition in asynchronous optical-sampling terahertz time-domain spectroscopy based on dual-comb system
- Resolving nonuniform temperature distributions with single-beam absorption spectroscopy. Part II: Implementation from broadband spectra
- Spectrum-free integrated photonic remote molecular identification and sensing
- An ultra-stable microresonator-based electro-optic dual frequency comb
- Demonstration of a uniform, high-pressure, high-temperature gas cell with a dual frequency comb absorption spectrometer
- Spectral characterization of a frequency comb based on cascaded quadratic nonlinearities inside an optical parametric oscillator
- Nonlinear transmission spectroscopy with dual frequency combs
- Jitter correction for asynchronous optical sampling terahertz spectroscopy using free-running pulsed lasers
- Robust asynchronous optical sampling terahertz spectroscopy using commercially available free-running lasers
- Frequency Comb-Based Remote Sensing of Greenhouse Gases over Kilometer Air Paths
- Comb-rooted multi-channel synthesis of ultra-narrow optical frequencies of few Hz linewidth
- Real-Time Electro-Optic Dual Comb Detection of Ultrasound Waves