The KamLAND Full-Volume Calibration System
arXiv:0903.0441 · doi:10.1088/1748-0221/4/04/P04017
Abstract
We have successfully built and operated a source deployment system for the KamLAND detector. This system was used to position radioactive sources throughout the delicate 1-kton liquid scintillator volume, while meeting stringent material cleanliness, material compatibility, and safety requirements. The calibration data obtained with this device were used to fully characterize detector position and energy reconstruction biases. As a result, the uncertainty in the size of the detector fiducial volume was reduced by a factor of two. Prior to calibration with this system, the fiducial volume was the largest source of systematic uncertainty in measuring the number of anti-neutrinos detected by KamLAND. This paper describes the design, operation and performance of this unique calibration system.
30 pages, 22 figures, to be submitted to JINST
References in corpus (3)
Cited by in corpus (26)
- Precision Measurement of Neutrino Oscillation Parameters with KamLAND
- Constraints on from A Three-Flavor Oscillation Analysis of Reactor Antineutrinos at KamLAND
- The next-generation liquid-scintillator neutrino observatory LENA
- Production of Radioactive Isotopes through Cosmic Muon Spallation in KamLAND
- Calibration Strategy of the JUNO Experiment
- 7Be Solar Neutrino Measurement with KamLAND
- KamLAND Sensitivity to Neutrinos from Pre-Supernova Stars
- Neutrino Oscillation Studies with Reactors
- Limits on astrophysical antineutrinos with the KamLAND experiment
- Neutrino emissions in all flavors up to the pre-bounce of massive stars and the possibility of their detections
- Precision -electron Scattering Measurements with IsoDAR to Search for New Physics
- Reactor Neutrino Experiments: Present and Future
- Neutrino mass hierarchy determination and other physics potential of medium-baseline reactor neutrino oscillation experiments
- Studying the Earth with Geoneutrinos
- Reactor antineutrino flux and anomaly
- Geoneutrinos and geoscience: an intriguing joint-venture
- Cable Loop Calibration System for Jiangmen Underground Neutrino Observatory
- Combined Pre-Supernova Alert System with Kamland and Super-Kamiokande
- A compact ultra-clean system for deploying radioactive sources inside the KamLAND detector
- Study of electron anti-neutrinos associated with gamma-ray bursts using KamLAND
- The Automatic Calibration Unit in JUNO
- Distributed Imaging for Liquid Scintillation Detectors
- Experimental Aspects of Geoneutrino Detection: Status and Perspectives
- Evaluation of the performance of the event reconstruction algorithms in the JSNS experiment using a Cf calibration source
- On the origin of the discrepancy between the expected and observed results at KamLAND
- Comprehensive neutrino light curves and spectra: from pre-supernova evolution to early supernova phase