Effective area calibration of the Reflection Grating Spectrometers of XMM-Newton. I. X-ray spectroscopy of the Crab nebula
arXiv:0902.1094 · doi:10.1051/0004-6361/20077892
Abstract
The Crab nebula and pulsar have been widely used as a calibration source for X-ray instruments. The in-flight effective area calibration of the Reflection Grating Spectrometers (RGS) of XMM-Newton depend upon the availability of reliable calibration sources. We investigate how the absolute effective area calibration of RGS can be obtained using Crab as a standard candle. We have analysed RGS observations of the Crab using different instrument configurations and spatial offsets, and made use of previous determinations of the continuum spectrum of the nebula plus pulsar. Due to the high spectral resolution of the RGS, we resolve the main absorption edges and detect the strong 1s-2p absorption lines of neutral oxygen. We get an excellent fit to the Crab spectrum using this fixed continuum and the absorption spectrum determined by RGS. We get accurate column densities for the neutral atoms of H, N, O, Ne, Mg, and Fe, as well as a clear detection of Fe II and firm upper limits for other ions. Our data are in good agreement with earlier optical and UV spectroscopic measurements of some of these ions. We find solar abundances for N and O, while Ne is overabundant by a factor of 1.7 and Fe is underabundant by a factor of 0.8. We confirm that there is less dust in the line of sight compared to the prediction based on the absorption column. Our spectra suggest a more prominent role of ferric iron in the dust compared to ferrous iron. Our high-resolution observations confirm that Crab can be used as an X-ray calibration source. RGS spectra have determined the absorption spectrum towards Crab with unprecedented detail.
23 pages, 15 figures, 2 appendices, accepted for publication in Astronomy & Astrophysics, main journal
References in corpus (5)
- Simulated synchrotron emission from Pulsar Wind Nebulae
- Neon Abundances in B-Stars of the Orion Association: Solving the Solar Model Problem?
- Spitzer Space Telescope Infrared Imaging and Spectroscopy of the Crab Nebula
- High-Resolution X-ray Spectroscopy of the Interstellar Medium II: Neon and Iron Absorption Edges
- Effective area calibration of the reflection grating spectrometers of XMM-Newton. II. X-ray spectroscopy of DA white dwarfs
Cited by in corpus (9)
- Dust absorption and scattering in the silicon K-edge
- Absorption and scattering by interstellar dust in the silicon K-edge of GX 5-1
- Calibration and in orbit performance of the reflection grating spectrometer onboard XMM-Newton
- Ray-tracing simulations and spectral models of X-ray radiation in dusty media
- Multiwavelength campaign on Mrk 509 IX. The Galactic foreground
- Multiwavelength Campaign on Mrk 509 X. Lower limit on the distance of the absorber from HST COS and STIS spectroscopy
- A study of the composite supernova remnant MSH 15-56 with Suzaku
- Effective area calibration of the reflection grating spectrometers of XMM-Newton. II. X-ray spectroscopy of DA white dwarfs
- A constant pressure model for the warm absorber in Mrk 509