Time resolution of a Thick Gas Electron Multiplier (THGEM) - based detector
arXiv:0809.4382 · doi:10.1088/1748-0221/3/11/P11001
Abstract
The time resolution of a double-stage Thick-GEM (THGEM) detector was measured with UV-photons and relativistic electrons. The photon detector, with semitransparent- or reflective-photocathode yielded time resolution of about 8-10ns RMS for single photoelectrons and 0.5-1ns RMS for few-hundred photoelectrons per photon-pulse. Time resolution of about 10ns RMS was recorded for relativistic electrons from a 106Ru source.
8 Pages, 10 Figures, Submitted to JINST
References in corpus (6)
- Thick GEM-like hole multipliers: properties and possible applications
- Advances in Thick GEM-like gaseous electron multipliers. Part I: atmospheric pressure operation
- Thick GEM-like multipliers - a simple solution for large area UV-RICH detectors
- Advances in Thick GEM-like gaseous electron multipliers. Part II: low-pressure operation
- Investigations of a THGEM-based imaging detector
- Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe
Cited by in corpus (8)
- Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4
- CsI-THGEM gaseous photomultipliers for RICH and noble-liquid detectors
- Laboratory studies of THGEM-based WELL structures with resistive anodes
- The Thick Gas Electron Multiplier and its derivatives: physics, technologies and applications
- Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier
- Performance of the triple GEM detector built using commercially manufactured GEM foils in India
- Electrical breakdown in Thick-GEM based WELL detectors
- Evolution and Recent Developments of the Gaseous Photon Detectors Technologies