Investigations of a THGEM-based imaging detector
arXiv:0707.3257 · doi:10.1088/1748-0221/2/09/P09002
Abstract
We present the results of our recent studies on a Thick Gas Electron Multiplier (THGEM)-based imaging detector prototype. It consists of two 100x100 mm^2 THGEM electrodes in cascade, coupled to a resistive anode. The event location is recorded with a 2D double-sided readout electrode equipped with discrete delay-lines and dedicated electronics. The THGEM electrodes, produced by standard printed-circuit board and mechanical drilling techniques, a 0.4 mm thick with 0.5 mm diameter holes spaced by 1 mm. Localization resolutions of about 0.7 mm (FWHM) were measured with soft x-rays, in a detector operated with atmospheric-pressure Ar/CH4; good linearity and homogeneity were achieved. We describe the imaging-detector layout, the resistive-anode 2D readout system and the imaging properties. The THGEM has numerous potential applications that require large-area imaging detectors, with high-rate capability, single-electron sensitivity and moderate (sub-mm) localization resolution.
Published in JINST, 22 pages, 18 figures
References in corpus (9)
- Thick GEM-like hole multipliers: properties and possible applications
- Advances in Thick GEM-like gaseous electron multipliers. Part I: atmospheric pressure operation
- Detection of the primary scintillation light from dense Ar, Kr and Xe with novel photosensitive gaseous detectors
- Thick GEM-like multipliers - a simple solution for large area UV-RICH detectors
- Position Sensing from Charge Dispersion in Micro-Pattern Gas Detectors with a Resistive Anode
- Advances in Thick GEM-like gaseous electron multipliers. Part II: low-pressure operation
- First Tests of Thick GEMs with Electrodes Made of a Resistive Kapton
- Detectors for Time-of-Flight Fast-Neutron Radiography: 1. Neutron Counting Gas Detector
- Advances in imaging THGEM-based detectors
Cited by in corpus (22)
- A concise review on THGEM detectors
- Advances in Gaseous Photomultipliers
- THGEM operation in Ne and Ne/CH4
- Thick GEM versus thin GEM in two-phase argon avalanche detectors
- Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4
- CsI-THGEM gaseous photomultipliers for RICH and noble-liquid detectors
- Operation of a Thick Gas Electron Multiplier (THGEM) in Ar, Xe and Ar-Xe
- Laboratory studies of THGEM-based WELL structures with resistive anodes
- Concept of a novel fast neutron imaging detector based on THGEM for fan-beam tomography applications
- A Comprehensive Simulation Study of a Liquid-Xe Detector for Contraband Detection
- Recent advances with THGEM detectors
- The Resistive-Plate WELL with Argon mixtures - a robust gaseous radiation detector
- Time resolution of a Thick Gas Electron Multiplier (THGEM) - based detector
- The Thick Gas Electron Multiplier and its derivatives: physics, technologies and applications
- Fast-neutron and gamma-ray imaging with a capillary liquid xenon converter coupled to a gaseous photomultiplier
- On the localization properties of an RPWELL gas-avalanche detector
- Beam induced space-charge effects in Time Projection Chambers in low-energy nuclear physics experiments
- Electrical breakdown in Thick-GEM based WELL detectors
- Evolution and Recent Developments of the Gaseous Photon Detectors Technologies
- Low-pressure THGEM-based operation with Ne+H2 Penning mixtures
- Cryogenic Gaseous Photomultiplier for Position Reconstruction of Liquid Argon Scintillation Light
- High-gain DC-mode operated Gaseous Photomultipliers for the visible spectral range