output
20082026
most citedOpen data from the third observing run of LIGO, Virgo, KAGRA and GEO

331 citations

Showing physics.med-phShow all

13 papers · 1 filter

physics.med-ph2025

Using an instrumented hammer during Summers osteotomy: an animal model

Yasuhiro Homma, Manon Bas Dit Nugues, Arnaud Dubory +5

Summers osteotomy is a technique used to increase bone height and to improve bone density in dental implant surgery. The two main risks of this surgery, which is done by impacting…

physics.med-ph2025

An Instrumented Hammer to Detect the Bone Transitions During an High Tibial Osteotomy: An Animal Study

Bas-Dit-Nugues Manon, Teddy Ketani, Claire Bastard +5

High tibial osteotomy is a common procedure for knee osteoarthritis during which the surgeon partially opens the tibia and must stop impacting when cortical bone is reached by the…

physics.med-ph2025

Estimation of the surface mechanical properties of soft tissues mimicking phantoms using impact analyses: a comparative study

Arthur Bouffandeau, Sabine Bensamoun, Robert Schleip +4

Background: Palpation is the most widely used approach to empirically assess the mechanical properties of superficial tissues. While elastography is used for volume measurements, i…

physics.med-ph2021★ 6 cited

Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction

Katharina Immel, Vu-Hieu Nguyen, Guillaume Haiat +1

Cementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the porous surf…

physics.med-ph2021

Using an Impact Hammer to Perform Biomechanical Measurements during Osteotomies: Study of an Animal Model

Léo Lamassoure, Justine Giunta, Giuseppe Rosi +4

Osteotomies are common surgical procedures used for instance in rhinoplasty and usually performed using an osteotome impacted by a mallet. Visual control being difficult, osteotomi…

physics.med-ph2020★ 142 cited

Stress shielding at the bone-implant interface: influence of surface roughness and of the bone-implant contact ratio

Maria Letizia Raffa, Vu-Hieu Nguyen, Philippe Hernigou +2

Short and long-term stabilities of cementless implants are strongly determined by the interfacial load transfer between implants and bone tissue. Stress-shielding effects arise fro…

physics.med-ph2020★ 31 cited

Ex vivo estimation of cementless femoral stem stability using an instrumented hammer

Hugues Albini Lomami, Camille Damour, Giuseppe Rosi +4

Background 15 The success of cementless hip arthroplasty depends on the primary stability of the femoral stem. It remains difficult to assess the optimal number of impacts to guara…

physics.med-ph2019★ 9 cited

A modified Coulomb's law for the tangential debonding of osseointegrated implants

Katharina Immel, Thang X. Duong, Vu-Hieu Nguyen +2

Cementless implants are widely used in orthopedic and oral surgery. However, debonding-related failure still occurs at the bone-implant interface. It remains difficult to predict s…

physics.med-ph2019★ 4 cited

Evaluation of dental implant stability in bone phantoms: comparison between a quantitative ultrasound technique and resonance frequency analysis

Romain Vayron, Vu Hieu Nguyen, Benoît Lecuelle +1

Background Resonance frequency analyses and quantitative ultrasound methods have been suggested to assess dental implant primary stability. PurposeThe purpose of this study was to…

physics.med-ph2019

Monitoring cementless femoral stem insertion by impact

Antoine Tijou, Giuseppe Rosi, Romain Vayron +4

The primary stability of the femoral stem (FS) implant determines the surgical success of cementless 15 hip arthroplasty. During the insertion, a compromise must be found for the n…

physics.med-ph2019★ 17 cited

Reflection of an ultrasonic wave on the bone-implant interface: effect of the roughness parameters

Yoann Hériveaux, Vu-Hieu Nguyen, Vladimir Brailovski +2

Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial…

physics.med-ph2019

Resonant frequency analysis of dental implants

D Rittel, A Dorogoy, G. Haiat +1

Dental implant stability influences the decision on the determination of the duration between implant insertion and loading, This work investigates the resonant frequency analysis…

physics.med-ph2018★ 1 cited

Three-dimensional Simulation of Quantitative Ultrasound in Cancellous Bone using the Echographic Response of a Metallic Pin

Yoshiki Nagatani, Séraphin Guipieri, Vu-Hieu Nguyen +4

Degenerative discopathy is a common pathology which may require spine surgery. A metallic cylindrical pin is inserted into the vertebral body to maintain soft tissues and may be us…