most citedStress shielding at the bone-implant interface: influence of surface roughness and of the bone-implant contact ratio

142 citations · 188 across the 7 of their papers we have counts for

collaborators

7 papers

physics.med-ph2021★ 6 cited

Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction

Katharina Immel, Vu-Hieu Nguyen, Guillaume Haiat +1

Cementless implants have become widely used for total hip replacement surgery. The long-term stability of these implants is achieved by bone growing around and into the porous surf…

physics.med-ph2020★ 142 cited

Stress shielding at the bone-implant interface: influence of surface roughness and of the bone-implant contact ratio

Maria Letizia Raffa, Vu-Hieu Nguyen, Philippe Hernigou +2

Short and long-term stabilities of cementless implants are strongly determined by the interfacial load transfer between implants and bone tissue. Stress-shielding effects arise fro…

physics.med-ph2019★ 9 cited

A modified Coulomb's law for the tangential debonding of osseointegrated implants

Katharina Immel, Thang X. Duong, Vu-Hieu Nguyen +2

Cementless implants are widely used in orthopedic and oral surgery. However, debonding-related failure still occurs at the bone-implant interface. It remains difficult to predict s…

physics.med-ph2019★ 4 cited

Evaluation of dental implant stability in bone phantoms: comparison between a quantitative ultrasound technique and resonance frequency analysis

Romain Vayron, Vu Hieu Nguyen, Benoît Lecuelle +1

Background Resonance frequency analyses and quantitative ultrasound methods have been suggested to assess dental implant primary stability. PurposeThe purpose of this study was to…

physics.med-ph2019★ 17 cited

Reflection of an ultrasonic wave on the bone-implant interface: effect of the roughness parameters

Yoann Hériveaux, Vu-Hieu Nguyen, Vladimir Brailovski +2

Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial…

physics.med-ph2018★ 1 cited

Three-dimensional Simulation of Quantitative Ultrasound in Cancellous Bone using the Echographic Response of a Metallic Pin

Yoshiki Nagatani, Séraphin Guipieri, Vu-Hieu Nguyen +4

Degenerative discopathy is a common pathology which may require spine surgery. A metallic cylindrical pin is inserted into the vertebral body to maintain soft tissues and may be us…

math.AP2015★ 9 cited

Transient thermal mixed boundary value problems in the half-space

William J. Parnell, Vu-Hieu Nguyen, Raphael Assier +2

The Wiener-Hopf and Cagniard-de Hoop techniques are employed in order to solve a range of transient thermal mixed boundary value problems on the half-space. The thermal field is de…