9.8k citations
Counting papers with at most 25 authors, so collaboration author lists do not stand in for the people here.
- Centre National de la Recherche ScientifiqueFR2.3k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di Roma IIT2.3k papers
- European Organization for Nuclear ResearchCH2.3k papers
- University of Milano-BicoccaIT2.2k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di GenovaIT2.2k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di BolognaIT2.1k papers
- Institut National de Physique Nucléaire et de Physique des ParticulesFR2.1k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di PisaIT2.1k papers
- Rutherford Appleton LaboratoryGB2k papers
- Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di FrascatiIT2k papers
- Istituto Nazionale di Fisica Nucleare, Sezione di FirenzeIT2k papers
- Massachusetts Institute of TechnologyUS2k papers
13 papers · 2 filters
Improving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout
M. Bonesini, R. Bertoni, A. Abba +3
LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier…
Analysis of reactor burnup simulation uncertainties for antineutrino spectrum prediction
A. Barresi, M. Borghesi, A. Cammi +64
Nuclear reactors are a source of electron antineutrinos due to the presence of unstable fission products that undergo decay. They will be exploited by the JUNO experiment to…
Improving the Performance of Cryogenic Calorimeters with Nonlinear Multivariate Noise Cancellation Algorithms
Kenneth J. Vetter, Mattia Beretta, Chiara Capelli +11
State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments i…
Autoencoder-based Anomaly Detection System for Online Data Quality Monitoring of the CMS Electromagnetic Calorimeter
The CMS ECAL Collaboration
The CMS detector is a general-purpose apparatus that detects high-energy collisions produced at the LHC. Online Data Quality Monitoring of the CMS electromagnetic calorimeter is a…
Test of CdWO and LiMoO scintillating bolometers in the CROSS underground facility with upgraded detector suspension
A. Ahmine, I. C. Bandac, A. S. Barabash +38
In preparation to the CROSS decay experiment, we installed a new detector suspension with magnetic dumping inside a pulse-tube cryostat of a dedicated low-background facility…
Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence
A. Bornheim, W. Lustermann, K. Stachon +27
The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in…
Array of Cryogenic Calorimeters to Evaluate the Spectral Shape of forbidden -decays: the ACCESS project
L. Pagnanini, G. Benato, P. Carniti +21
The ACCESS (Array of Cryogenic Calorimeters to Evaluate Spectral Shapes) project aims to establish a novel technique to perform precision measurements of forbidden \b{eta}-decays,…
LiMoO Scintillating Bolometers for Rare-Event Search Experiments
I. C. Bandac, A. S. Barabash, L. Bergé +35
We report on the development of scintillating bolometers based on lithium molybdate crystals containing molybdenum depleted in the double- active isotope Mo (Li$^{10…
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaboration, K. Alfonso, A. Armatol +176
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of Mo. It will operate at 10 mK…
Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
CUPID, CROSS collaborations, : +182
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS…
Enhanced light signal for the suppression of pile-up events in Mo-based bolometers for the decay search
A. Ahmine, A. Armatol, I. Bandac +24
Random coincidences of events could be one of the main sources of background in the search for neutrino-less double-beta decay of Mo with macro-bolometers, due to their mod…
Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics
Riccardo Triozzi, Andrea Serafini, Marco Bellato +129
The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-p…
Mass testing of the JUNO experiment 20-inch PMTs readout electronics
Alberto Coppi, Beatrice Jelmini, Marco Bellato +129
The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measureme…