activity
20132025
most citedDark Matter Results From 54-Ton-Day Exposure of PandaX-II Experiment

915 citations · 4.1k across the 68 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

8 papers · 1 filter

physics.ins-det2020★ 16 cited

Cable Loop Calibration System for Jiangmen Underground Neutrino Observatory

Yuanyuan Zhang, Jiaqi Hui, Jianglai Liu +6

A cable loop source calibration system is developed for the Jiangmen Underground Neutrino Observatory, a 20 kton spherical liquid scintillator neutrino experiment. This system is c…

physics.ins-det2020★ 16 cited

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

Wenbo Ma, Abdusalam Abdukerim, Zihao Bo +65

We have developed a low-energy electron recoil (ER) calibration method with Rn for the PandaX-II detector. Rn, emanated from natural thorium compounds, was fed into…

physics.ins-det2019★ 13 cited

Design of Guide Tube Calibration System for JUNO Experiment

Yuhang Guo, Qingmin Zhang, Feiyang Zhang +3

Jiangmen Underground Neutrino Observatory (JUNO) is designed to determine the neutrino mass hierarchy using a 20 kton liquid scintillator detector. To calibrate detector boundary e…

physics.ins-det2018★ 161 cited

Dark matter direct search sensitivity of the PandaX-4T experiment

Hongguang Zhang, Abdusalam Abdukerim, Xun Chen +57

The PandaX-4T experiment, a four-ton scale dark matter direct detection experiment, is being planned at the China Jinping Underground Laboratory. In this paper we present a simulat…

physics.ins-det2017★ 8 cited

Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

M. Dragicevic, M. Friedl, J. Hrubec +481

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…

physics.ins-det2015★ 13 cited

Performance of Photosensors in the PandaX-I Experiment

Shaoli Li, Xun Chen, Karl L. Giboni +10

We report the long term performance of the photosensors, 143 one-inch R8520-406 and 37 three-inch R11410-MOD photomultipliers from Hamamatsu, in the first phase of the PandaX dual-…

physics.ins-det2014★ 15 cited

PandaX: A Liquid Xenon Dark Matter Experiment at CJPL

X. G. Cao, X. Chen, Y. H. Chen +47

PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and Xe double-beta decay search. It is located in the Jinpi…

physics.ins-det2013★ 3 cited

Development of the Liquid Level Meters for the PandaX Dark Matter Detector

J. Hu, H. Gong, Q. Lin +6

The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/g…