activity
20132026
most citedSearch for Majorana neutrinos with the first two years of EXO-200 data

437 citations · 2k across the 34 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

16 papers · 1 filter

physics.ins-det2026

EXO-200 Public Data Release for AI/ML Applications

S. Al Kharusi, G. Anton, I. Badhrees +103

We present a public release of a subset of calibration data from the EXO-200 experiment, a liquid xenon time projection chamber designed to search for neutrinoless double-beta deca…

physics.ins-det2024★ 3 cited

Ion manipulation from liquid Xe to vacuum: Ba-tagging for a nEXO upgrade and future experiments

Dwaipayan Ray, Robert Collister, Hussain Rasiwala +27

Neutrinoless double beta decay {()} provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for decay i…

physics.ins-det2021★ 10 cited

The EXO-200 detector, part II: Auxiliary Systems

N. Ackerman, J. Albert, M. Auger +157

The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…

physics.ins-det2019★ 34 cited

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

200 Collaboration, G. Anton, I. Badhrees +99

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and i…

physics.ins-det2018★ 11 cited

Study of Silicon Photomultiplier Performance in External Electric Fields

X. L. Sun, T. Tolba, G. F. Cao +149

We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…

physics.ins-det2018★ 43 cited

VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO

A. Jamil, T. Ziegler, P. Hufschmidt +140

Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…

physics.ins-det2018★ 77 cited

nEXO Pre-Conceptual Design Report

nEXO Collaboration, S. Al Kharusi, A. Alamre +171

The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…

physics.ins-det2018★ 39 cited

Deep Neural Networks for Energy and Position Reconstruction in EXO-200

S. Delaquis, M. J. Jewell, I. Ostrovskiy +91

We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position -…

physics.ins-det2017★ 25 cited

Characterization of an Ionization Readout Tile for nEXO

nEXO Collaboration, M. Jewell, A. Schubert +142

A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…

physics.ins-det2017★ 32 cited

Trace radioactive impurities in final construction materials for EXO-200

D. S. Leonard, D. Auty, T. Didberidze +98

We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial…

physics.ins-det2016★ 52 cited

Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector

200 Collaboration, J. B. Albert, P. S. Barbeau +84

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of c…

physics.ins-det2016★ 10 cited

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

200 Collaboration, C. G. Davis, C. Hall +84

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal s…

physics.ins-det2015★ 45 cited

Investigation of radioactivity-induced backgrounds in EXO-200

J. B. Albert, D. J. Auty, P. S. Barbeau +83

The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of pa…

physics.ins-det2014★ 47 cited

An RF-only ion-funnel for extraction from high-pressure gases

Thomas Brunner, Daniel Fudenberg, Victor Varentsov +74

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into vacuum ( mbar). Detailed simulations have been perfo…

physics.ins-det2014★ 21 cited

An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe

K. Twelker, S. Kravitz, M. Montero Díez +77

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to…

physics.ins-det2013★ 12 cited

Ba-ion extraction from a high pressure Xe gas for double-beta decay studies with EXO

T. Brunner, D. Fudenberg, A. Sabourov +3

An experimental setup is being developed to extract Ba ions from a high-pressure Xe gas environment. It aims to transport Ba ions from 10 bar Xe to vacuum conditions. The setup uti…