84 citations · 415 across the 34 of their papers we have counts for
35 papers
Improved Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA
R. Mucciola, S. Cristallo, S. Kopecky +140
We report high-resolution measurements of the cross section in the neutron energy range from a few eV up to about 250 keV, performe…
First Nb() Measurement: Constraining the Nucleosynthetic Origin of Mo in Presolar Grains
J. Balibrea-Correa, J. Lerendegui-Marco, C. Domingo-Pardo +136
Isotopic measurements of presolar silicon carbide grains from dying stars have revealed a puzzling overabundance of Mo that stellar nucleosynthesis models have failed to rep…
Direct Experiments of Neutron Capture on Stable and Unstable Isotopes for Stellar Nucleosynthesis Studies
Jorge Lerendegui-Marco, Javier Balibrea-Correa, Victor Babiano-Suárez +7
Neutron-capture reactions provide essential nuclear-physics input for modeling the synthesis of heavy elements in stars. The growing precision of stellar spectroscopy and isotopic…
Measurement of the cross-section at the CERN n\_TOF facility from subthermal energy to 120 keV
Marco Antonio Martínez-Cañadas, Pablo Torres-Sánchez, Javier Praena +130
Background: The reaction is of special interest in three different applications. First, in Boron Neutron Capture Therapy due to the presence of in b…
Measurement of the C(n,p) and C(n,d) reactions from n_TOF at CERN
P. Žugec, N. Colonna, D. Rochman +129
The energy dependence of the cross section of the (n,p) and (n,d) reactions on C has been studied for the first time at the n_TOF facility at CERN, from the particle d…
Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade
J. A. Pavon-Rodriguez, J. Lerendegui-Marco, A. Manna +16
The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experi…
Neutron capture measurements for s-process nucleosynthesis; A review about CERN n_TOF developments and contributions
C. Domingo-Pardo, O. Aberle, V. Alcayne +143
This article presents a review about the main CERN n\_TOF contributions to the field of neutron-capture experiments of interest for -process nucleosynthesis studies over the las…
-delayed neutron spectroscopy of As with MONSTER at IGISOL
A. Pérez de Rada Fiol, T. Martínez, D. Cano-Ott +35
The -delayed neutron emission in the As -decays has been measured at the Ion Guide Isotope Separator On Line facility of the Accelerator Laboratory of the Universi…
Radiative neutron capture cross section of Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV
J. Lerendegui-Marco, C. Guerrero, E. Mendoza +133
Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For Pu, the Nuclear Energy Agency (NEA) recommends 8--1…
Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams
J. Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +134
Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn,…
A Segmented Total Energy Detector (sTED) optimized for cross-section measurements at n_TOF EAR2
V. Alcayne, D. Cano-Ott, J. Garcia +12
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, a…
New insights on fission of U induced by high energy neutrons from a new measurement at CERN n\_TOF
Alice Manna, Elisa Pirovano, the n\_TOF Collaboration
The U(n,f) reaction cross section was measured relative to neutron-proton elastic scattering for the first time in the energy region from 10 MeV to 440 MeV at the CERN n\_T…
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
J. Balibrea Correa, J. Lerendegui-Marco, V. Babiano-Suarez +131
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterizat…
Recent highlights and prospects on (n,) measurements at the CERN n_TOF facility
J. Lerendegui-Marco, V. Alcayne, V. Babiano-Suarez +12
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear te…
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
N Mont-Geli, A Tarifeño-Saldivia, L M Fraile +40
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (…
miniBELEN: a modular neutron counter for (alpha,n) reactions
N Mont-Geli, A Tarifeño-Saldivia, L M Fraile +38
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reasse…
New perspectives for neutron capture measurements in the upgraded CERN-n_TOF Facility
J. Lerendegui-Marco, A. Casanovas, V. Alcayne +1
The n_TOF facility has just undergone in 2021 a major upgrade with the installation of its third generation spallation target that has been designed to optimize the performance of…
New detection systems for an enhanced sensitivity in key stellar (n,) measurements
J. Lerendegui-Marco, V. Babiano-Suárez, J. Balibrea-Correa +17
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in re…
First measurement of the Nb(,) cross section at the CERN n\_TOF facility
J. Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +134
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the -,…
The CERN n TOF NEAR station for astrophysics- and application-related neutron activation measurements
N. Patronis, A. Mengoni, N. Colonna +130
A new experimental area, the NEAR station, has recently been built at the CERN n TOF facility, at a short distance from the spallation target (1.5 m). The new area, characterized b…
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
C. Domingo-Pardo, V. Babiano-Suarez, J. Balibrea-Correa +136
This article presents a few selected developments and future ideas related to the measurement of data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodo…
Simultaneous Gamma-Neutron Vision device: a portable and versatile tool for nuclear inspections
J. Lerendegui Marco, V. Babiano-Suárez, J. Balibrea-Correa +4
GN-Vision is a novel dual -ray and neutron imaging system, which aims at simultaneously obtaining information about the spatial origin of -ray and neutron sources. The propos…
High accuracy, high resolution 235U(n,f) cross section from n_TOF (CERN) in the thermal to 10 keV energy range
TOF collaboration, M. Mastromarco, S. Amaducci +119
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with hig…
Towards machine learning aided real-time range imaging in proton therapy
Jorge Lerendegui-Marco, Javier Balibrea-Correa, Víctor Babiano-Súarez +2
In this work, we report on the advantageous aspects of the i-TED Compton imager for proton-range monitoring, based on the results of the first Monte Carlo study of its applicabilit…