9 citations · 15 across the 8 of their papers we have counts for
9 papers
Towards real-time ion range verification via hybrid Compton-PET 3D imaging at isochronous cyclotrons
Javier Balibrea-Correa, V. Babiano-Suarez, J. Lerendegui-Marco +8
Range uncertainties remain a major limitation to the full clinical exploitation of proton therapy, motivating reliable in-vivo range-verification techniques. This work presents an…
Hybrid Compton-PET Imaging for ion-range verification:A Preclinical Study for Proton-, Helium-, and Carbon-Therapy at HIT
Javier Balibrea-Correa, Jorge Lerendegui-Marco, Ion Ladarescu +8
Enhanced-accuracy ion-range verification in real time shall enable a significant step forward in the use of therapeutic ion beams. Positron-emission tomography (PET) and prompt-gam…
A computer-vision aided Compton-imaging system for radioactive waste characterization and decommissioning of nuclear power plants
Victor Babiano-Suarez, Javier Balibrea-Correa, Ion Ladarescu +3
Nuclear energy production is inherently tied to the management and disposal of radioactive waste. Enhancing classification and monitoring tools is therefore crucial, with significa…
Towards Real Time Compton Imaging in Demanding Conditions
Bernardo Gameiro, Jorge Lerendegui-Marco, Victor Babiano-Suarez +5
Compton cameras are radiation detectors that provide spatial information on the origin of the γ-ray sources based on the Compton scattering effect. Many applications require these…
Imaging neutrons with a position-sensitive monolithic CLYC detector
J. Lerendegui-Marco, G. Cisterna, J. Hallam +9
In this work, we have developed and characterized a position-sensitive CLYC detector that acts as the neutron imaging layer and -ray Compton scatterer of the novel dual \g-ray a…
The i-TED Compton Camera Array for real-time boron imaging and determination during treatments in Boron Neutron Capture Therapy
Pablo Torres-Sánchez, Jorge Lerendegui-Marco, Javier Balibrea-Correa +12
This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in…
First Pilot Tests of Compton Imaging and Boron Concentration Measurements in BNCT Using i-TED
J. Lerendegui-Marco, J. Balibrea-Correa, P. Álvarez-Rodríguez +10
Dosimetry in BNCT poses significant challenges due to the indirect effect of neutrons interacting with elements within the body and uncertainties associated with the uptake of boro…
Measurement and analysis of the Cm and Cm neutron capture cross-sections at the EAR2 of the n TOF facility
V. Alcayne, A. Kimura, E. Mendoza +130
The Cm(n,) and Cm(n,) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three CD detectors. This…
Hybrid in-beam PET- and Compton prompt-gamma imaging aimed at enhanced proton-range verification
Javier Balibrea-Correa, Jorge Lerendegui-Marco, Ion Ladarescu +5
We report on an hybrid in-beam PET and prompt-gamma Compton imaging system aimed at quasi real-time ion-range verification in proton-therapy treatments. Proof-of-concept experiment…