432 citations · 5.6k across the 53 of their papers we have counts for
53 papers
Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map
Ivan Alonso, Cristiano Alpigiani, Brett Altschul +246
We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportu…
Prospects for Fundamental Physics with LISA
Enrico Barausse, Emanuele Berti, Thomas Hertog +318
In this paper, which is of programmatic rather than quantitative nature, we aim to further delineate and sharpen the future potential of the LISA mission in the area of fundamental…
The unit of time: present and future directions
S. Bize
Some 50~years ago, physicists, and after them the entire world, started to found their time reference on atomic properties instead of motions of the Earth that have been in use sin…
Direct comparisons of European primary and secondary frequency standards via satellite techniques
F. Riedel, A. Al-Masoudi, E. Benkler +46
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-bas…
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
B. M. Roberts, P. Delva, A. Al-Masoudi +51
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in…
First international comparison of fountain primary frequency standards via a long distance optical fiber link
J. Guéna, S. Weyers, M. Abgrall +25
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-S…
Improved Tests of Lorentz Invariance in the Matter Sector using Atomic Clocks
H. Pihan-Le Bars, C. Guerlin, Q. G. Bailey +2
For the purpose of searching for Lorentz-invariance violation in the minimal Standard-Model Extension, we perfom a reanalysis of data obtained from the fountain c…
Determination of a high spatial resolution geopotential model using atomic clock comparisons
Guillaume Lion, Isabelle Panet, Peter Wolf +3
Recent technological advances in optical atomic clocks are opening new perspectives for the direct determination of geopotential differences between any two points at a centimeter-…
Lorentz-symmetry test at Planck-scale suppression with nucleons in a spin-polarized Cs cold atom clock
H. Pihan-Le Bars, C. Guerlin, R. -D. Lasseri +5
We introduce an improved model that links the frequency shift of the hyperfine Zeeman transitions to th…
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Jérôme Lodewyck, Sławomir Bilicki, Eva Bookjans +10
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude…
Searching for an oscillating massive scalar field as a dark matter candidate using atomic hyperfine frequency comparisons
A. Hees, J. Guéna, M. Abgrall +2
We use six years of accurate hyperfine frequency comparison data of the dual rubidium and caesium cold atom fountain FO2 at LNE-SYRTE to search for a massive scalar dark matter can…
Development of a strontium optical lattice clock for the SOC mission on the ISS
S. Origlia, S. Schiller, M. S. Pramod +25
The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests…
Comparing a mercury optical lattice clock with microwave and optical frequency standards
R Tyumenev, M Favier, S Bilicki +9
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of . Comparing this characterized fre…
Atomic fountains and optical clocks at SYRTE: status and perspectives
M. Abgrall, B. Chupin, L. De Sarlo +9
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application t…
Development of a strontium optical lattice clock for the SOC mission on the ISS
K. Bongs, Y. Singh, L. Smith +24
Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) pro…
Contributing to TAI with a Secondary Representation of the SI Second
Jocelyne Guéna, Michel Abgrall, André Clairon +1
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain f…
Testing local position and fundamental constant invariance due to periodic gravitation and boost using long-term comparison of the SYRTE atomic fountains and H-masers
M. E. Tobar, P. L. Stanwix, J. J. McFerran +8
The frequencies of three separate Cs fountain clocks and one Rb fountain clock have been compared to various hydrogen masers to search for periodic changes correlated with the chan…
Experimenting an optical second with strontium lattice clocks
R. Le Targat, L. Lorini, Y. Le Coq +17
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, rea…
Laser locking to the 199Hg clock transition with 5.4x10^(-15)/sqrt(tau) fractional frequency instability
J. J. McFerran, D. V. Magalhaes, C. Mandache +5
With Hg atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm in which the full-width at half-maximum is <15Hz. Here we lock an…
The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems
S. Schiller, A. Görlitz, A. Nevsky +28
The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of Ge…
Feshbach resonances in Cesium at Ultra-low Static Magnetic Fields
D. J. Papoular, S. Bize, A. Clairon +3
We have observed Feshbach resonances for 133Cs atoms in two different hyperfine states at ultra-low static magnetic fields by using an atomic fountain clock. The extreme sensitivit…
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Jocelyne Guéna, Michel Abgrall, Daniele Rovera +5
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks.…
Progress in Atomic Fountains at LNE-SYRTE
Jocelyne Guéna, Michel Abgrall, Daniele Rovera +10
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five y…
A neutral atom frequency reference in the deep UV with 10^(-15) range uncertainty
J. J. McFerran, L. Yi, S. Mejri +5
We present an assessment of the (6s^{2})1S0 -> (6s7s)3P0 clock transition frequency in 199Hg with an uncertainty reduction of nearly three orders of magnitude and demonstrate an at…