185 citations · 2.3k across the 240 of their papers we have counts for
10 papers · 1 filter
Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors
ATLAS Collaboration
After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in exces…
Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector
ATLAS Collaboration
Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the s…
Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum
ATLAS Collaboration
Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgroun…
Performance of the ATLAS forward proton Time-of-Flight detector in Run 2
ATLAS Collaboration
We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-s…
The ATLAS Experiment at the CERN Large Hadron Collider: A Description of the Detector Configuration for Run 3
ATLAS Collaboration
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of $\mathcal{L}=2\times 10^{34}\mathr…
RE3/1 and RE4/1 RPC chambers integration in the inner region of the forward muon spectrometer in the CMS experiment
E. Voevodina, I. Crotty
The high pseudorapidity () region of the Compact Muon Solenoid (CMS) muon system is covered by Cathode Strip Chambers only and lacks redundant coverage despite the fact that it…
Layout and Assembly Technique of the GEM Chambers for the Upgrade of the CMS First Muon Endcap Station
Aashaq Shah, CMS-Muon Collaboration
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high ra…
The CMS RPC Detector Performance and Stability during LHC RUN-2
M. A. Shah, R. Hadjiska
The CMS experiment, located at the Large Hadron Collider (LHC) in CERN, has a redundant muon system composed by three different gaseous detector technologies: Cathode Strip Chamber…
High Rate RPC detector for LHC
F. Lagarde, A. Fagot, M. Gul +99
The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of…
RPC upgrade project for CMS Phase II
M. I. Pedraza-Morales
The Muon Upgrade Phase II of the Compact Muon Solenoid (CMS) aims to guarantee the optimal conditions of the present system and extend the coverage to ensure a reliable system…