747 citations · 1.7k across the 15 of their papers we have counts for
9 papers · 1 filter
Design and production of the high voltage electrode grids and electron extraction region for the LZ dual-phase xenon time projection chamber
R. Linehan, R. L. Mannino, A. Fan +46
The dual-phase xenon time projection chamber (TPC) is a powerful tool for direct-detection experiments searching for WIMP dark matter, other dark matter models, and neutrinoless do…
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
D. S. Akerib, C. W. Akerlof, D. Yu. Akimov +387
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above cm for a WIMP mass…
Investigation of background electron emission in the LUX detector
D. S. Akerib, S. Alsum, H. M. Araújo +93
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. Whil…
Liquid xenon scintillation measurements and pulse shape discrimination in the LUX dark matter detector
The LUX Collaboration, D. S. Akerib, S. Alsum +90
Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark matter and are expected to produce nuclear recoil (NR) events within liquid xenon time-projection cham…
Position Reconstruction in LUX
LUX Collaboration, D. S. Akerib, S. Alsum +91
The position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a…
LUX-ZEPLIN (LZ) Technical Design Report
B. J. Mount, S. Hans, R. Rosero +259
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achi…
Low-energy (0.7-74 keV) nuclear recoil calibration of the LUX dark matter experiment using D-D neutron scattering kinematics
LUX Collaboration, D. S. Akerib, S. Alsum +104
The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Underground Research Facility in Lead, South Dakota…
Tritium calibration of the LUX dark matter experiment
LUX Collaboration, D. S. Akerib, H. M. Araújo +98
We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170,000 highly pure and spatially-uniform tritium decays. We reconstruct the…
LUX-ZEPLIN (LZ) Conceptual Design Report
The LZ Collaboration, D. S. Akerib, C. W. Akerlof +192
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the p…