442 citations · 10.6k across the 382 of their papers we have counts for
22 papers · 1 filter
High-level hadronic tau lepton triggers of the CMS experiment in proton-proton collisions at = 13.6 TeV
CMS Collaboration
The trigger system of the CMS detector is pivotal in the acquisition of data for physics measurements and searches. Studies of final states characterized by hadronic decays of tau…
Performance of heavy-flavour jet identification in Lorentz-boosted topologies in proton-proton collisions at = 13 TeV
CMS Collaboration
Measurements in the highly Lorentz-boosted regime provoke increased interest in probing the Higgs boson properties and in searching for particles beyond the standard model at the L…
Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
CMS Collaboration
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisi…
Performance of the CMS high-level trigger during LHC Run 2
CMS Collaboration
The CERN LHC provided proton and heavy ion collisions during its Run 2 operation period from 2015 to 2018. Proton-proton collisions reached a peak instantaneous luminosity of 2.1 $…
Performance of the CMS electromagnetic calorimeter in pp collisions at = 13 TeV
CMS Collaboration
The operation and performance of the Compact Muon Solenoid (CMS) electromagnetic calorimeter (ECAL) are presented, based on data collected in pp collisions at = 13 TeV a…
Portable acceleration of CMS computing workflows with coprocessors as a service
CMS Collaboration
Computing demands for large scientific experiments, such as the CMS experiment at the CERN LHC, will increase dramatically in the next decades. To complement the future performance…
Development of the CMS detector for the CERN LHC Run 3
CMS Collaboration
Since the initial data taking of the CERN LHC, the CMS experiment has undergone substantial upgrades and improvements. This paper discusses the CMS detector as it is configured for…
Performance and Moli`ere radius measurements using a compact prototype of LumiCal in an electron test beam
H. Abramowicz, A. Abusleme, K. Afanaciev +51
A new design of a detector plane of sub-millimetre thickness for an electromagnetic sampling calorimeter is presented. It is intended to be used in the luminometers LumiCal and Bea…
Precision measurement of the structure of the CMS inner tracking system using nuclear interactions
CMS Collaboration
The structure of the CMS inner tracking system has been studied using nuclear interactions of hadrons striking its material. Data from proton-proton collisions at a center-of-mass…
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
M. Dragicevic, M. Friedl, J. Hrubec +481
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detecto…
Measurement of shower development and its Molière radius with a four-plane LumiCal test set-up
H. Abramowicz, A. Abusleme, K. Afanaciev +57
A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The obj…
Impact of low-dose electron irradiation on n+p silicon strip sensors
The Tracker Group of the CMS Collaboration
The response of n+p silicon strip sensors to electrons from a Sr-90 source was measured using a multi-channel read-out system with 25 ns sampling time. The measurements were perfor…
Investigation of a direction sensitive sapphire detector stack at the 5 GeV electron beam at DESY-II
O. Karacheban, K. Afanaciev, M. Hempel +6
Extremely radiation hard sensors are needed in particle physics experiments to instrument the region near the beam pipe. Examples are beam halo and beam loss monitors at the Large…
ECFA Detector R&D Panel, Review Report
The FCAL Collaboration, H. Abramowicz, A. Abusleme +68
Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low ang…
Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector
The FCAL Collaboration, H. Abramowicz, A. Abusleme +66
Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detec…
Fast Beam Condition Monitor for CMS: performance and upgrade
Jessica L. Leonard, Alan Bell, Piotr Burtowy +14
The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector…
Measurement of the Luminosity in the ZEUS Experiment at HERA II
L. Adamczyk, J. Andruszkow, T. Bold +34
The luminosity in the ZEUS detector was measured using photons from electron bremsstrahlung. In 2001 the HERA collider was upgraded for operation at higher luminosity. At the same…
Infrastructure for Detector Research and Development towards the International Linear Collider
J. Aguilar, P. Ambalathankandy, T. Fiutowski +274
The EUDET-project was launched to create an infrastructure for developing and testing new and advanced detector technologies to be used at a future linear collider. The aim was to…
Luminometer for the future International Linear Collider - simulation and beam test results
J. A. Aguilar, S. Kulis, W. Wierba +17
LumiCal will be the luminosity calorimeter for the proposed International Large Detector of the International Linear Collider (ILC). The ILC physics program requires the integrated…
Performance of the Fast Beam Conditions Monitor BCM1F of CMS in the first running periods of LHC
R. S. Schmidt, A. J. Bell, E. Castro +8
The Beam Conditions and Radiation Monitoring System, BRM, is implemented in CMS to protect the detector and provide an interface to the LHC. Seven sub-systems monitor beam conditio…
Forward Instrumentation for ILC Detectors
Halina Abramowicz, Angel Abusleme, Konstantin Afanaciev +55
Two special calorimeters are foreseen for the instrumentation of the very forward region of the ILC detector, a luminometer designed to measure the rate of low angle Bhabha scatter…
Fast Beam Conditions Monitor BCM1F for the CMS Experiment
A. Bell, E. Castro, R. Hall-Wilton +8
The CMS Beam Conditions and Radiation Monitoring System, BRM, will support beam tuning, protect the CMS detector from adverse beam conditions, and measure the accumulated dose clos…