Operation and performance of the CMS silicon strip tracker with proton-proton collisions at the CERN LHC
arXiv:2506.17195 · doi:10.1088/1748-0221/20/08/P08027
Abstract
Salient aspects of the commissioning, calibration, and performance of the CMS silicon strip tracker are discussed, drawing on experience during operation with proton-proton collisions delivered by the CERN LHC. The data were obtained with a variety of luminosities. The operating temperature of the strip tracker was changed several times during this period and results are shown as a function of temperature in several cases. Details of the system performance are presented, including occupancy, signal-to-noise ratio, Lorentz angle, and single-hit spatial resolution. Saturation effects in the APV25 readout chip preamplifier observed during early Run 2 are presented, showing the effect on various observables and the subsequent remedy. Studies of radiation effects on the strip tracker are presented both for the optical readout links and the silicon sensors. The observed effects are compared to simulation, where available, and they generally agree well with expectations.
arXiv commentReplaced with the published version. Added the journal reference and the DOI. All the figures and tables can be found at http://cms-results.web.cern.ch/cms-results/public-results/publications/TRK-20-002 (CMS Public Pages)
References in corpus (9)
- Description and performance of track and primary-vertex reconstruction with the CMS tracker
- Measurements of Inclusive W and Z Cross Sections in pp Collisions at sqrt(s)=7 TeV
- Search for long-lived charged particles in proton-proton collisions at sqrt(s) = 13 TeV
- Commissioning and Performance of the CMS Silicon Strip Tracker with Cosmic Ray Muons
- Stand-alone Cosmic Muon Reconstruction Before Installation of the CMS Silicon Strip Tracker
- Strategies and performance of the CMS silicon tracker alignment during LHC Run 2
- The CMS Tracker Readout Front End Driver
- Performance studies of the CMS Strip Tracker before installation
- An algorithm for calculating the Lorentz angle in silicon detectors