activity
20112019
most citedAn improved limit to the diffuse flux of ultra-high energy neutrinos from the Pierre Auger Observatory

179 citations · 680 across the 13 of their papers we have counts for

collaborators

13 papers

physics.ins-det2019★ 38 cited

First operation of the KATRIN experiment with tritium

M. Aker, K. Altenmüller, M. Arenz +168

The determination of the neutrino mass is one of the major challenges in astroparticle physics today. Direct neutrino mass experiments, based solely on the kinematics of beta-decay…

physics.ins-det2019★ 17 cited

High-resolution spectroscopy of gaseous Kr conversion electrons with the KATRIN experiment

K. Altenmüller, M. Arenz, W. -J. Baek +124

In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous Kr with the Karlsruhe Tritium…

physics.ins-det2019★ 14 cited

Gamma-induced background in the KATRIN main spectrometer

K. Altenmüller, M. Arenz, W. -J. Baek +123

The KATRIN experiment aims to measure the effective electron antineutrino mass with a sensitivity of 0.2 eV/c using a gaseous tritium source combined with th…

astro-ph.HE2018★ 133 cited

Large-scale cosmic-ray anisotropies above 4 EeV measured by the Pierre Auger Observatory

The Pierre Auger Collaboration, A. Aab, P. Abreu +374

We present a detailed study of the large-scale anisotropies of cosmic rays with energies above 4 EeV measured using the Pierre Auger Observatory. For the energy bins [4,8] EeV and…

physics.ins-det2018★ 28 cited

The KATRIN Superconducting Magnets: Overview and First Performance Results

M. Arenz, W. -J. Baek, M. Beck +121

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magne…

physics.ins-det2018★ 22 cited

Calibration of high voltages at the ppm level by the difference of Kr conversion electron lines at the KATRIN experiment

M. Arenz, W. -J. Baek, M. Beck +124

The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-…

physics.ins-det2018★ 29 cited

First transmission of electrons and ions through the KATRIN beamline

M. Arenz, W. -J. Baek, M. Beck +126

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a prec…

physics.ins-det2016★ 8 cited

Signals induced by charge-trapping in EDELWEISS FID detectors: analytical modeling and applications

The EDELWEISS Collaboration, Q. Arnaud, E. Armengaud +47

The EDELWEISS-III direct dark matter search experiment uses cryogenic HP-Ge detectors Fully covered with Inter-Digitized electrodes (FID). They are operated at low fields ($<1\;\ma…

astro-ph.HE2015★ 179 cited

An improved limit to the diffuse flux of ultra-high energy neutrinos from the Pierre Auger Observatory

The Pierre Auger Collaboration, Alexander Aab, Pedro Abreu +462

Neutrinos in the cosmic ray flux with energies near 1 EeV and above are detectable with the Surface Detector array of the Pierre Auger Observatory. We report here on searches throu…

physics.ins-det2013★ 38 cited

Design and operation of ARGONTUBE: a 5 m long drift liquid argon TPC

A. Ereditato, C. C. Hsu, S. Janos +7

The Liquid Argon Time Projection Chamber (LArTPC) is a prime type of detector for future large-mass neutrino observatories and proton decay searches. In this paper we present the d…

astro-ph.HE2012★ 7 cited

Radar reflection off extensive air showers

J. Stasielak, S. Baur, M. Bertaina +24

We investigate the possibility of detecting extensive air showers by the radar technique. Considering a bistatic radar system and different shower geometries, we simulate reflectio…

astro-ph.CO2012★ 127 cited

A search for low-mass WIMPs with EDELWEISS-II heat-and-ionization detectors

EDELWEISS Collaboration, E. Armengaud, C. Augier +52

We report on a search for low-energy (E < 20 keV) WIMP-induced nuclear recoils using data collected in 2009 - 2010 by EDELWEISS from four germanium detectors equipped with thermal…

astro-ph.HE2011★ 40 cited

Search for signatures of magnetically-induced alignment in the arrival directions measured by the Pierre Auger Observatory

The Pierre Auger Collaboration, P. Abreu, M. Aglietta +496

We present the results of an analysis of data recorded at the Pierre Auger Observatory in which we search for groups of directionally-aligned events (or `multiplets') which exhibit…