511 citations · 5.6k across the 152 of their papers we have counts for
75 papers · 1 filter
A microwave SQUID multiplexing concept for macro-cryogenic calorimeter arrays
N. Ferreiro Iachellini, P. Szypryt, L. Canonica +10
Massive cryogenic calorimeters read out by transition-edge sensors (TES) can reach eV-scale baseline resolution, but the single-channel dc-SQUID readout conventionally used in rare…
A rapid low-background assay of Pb in archaeological lead
M. Consonni, M. Clemenza, E. Di Stefano +11
In this work, we present a fast and highly efficient method for the measurement of Pb in metallic archaeological lead using the commercial low-background liquid scintillati…
Probing dark matter interactions with a RES-NOVA prototype cryogenic detector
D. Alloni, G. Benato, P. Carniti +44
We report on the operation of a 13 g PbWO crystal, grown from archaeological Pb and operated as a cryogenic calorimeter in an underground environment. Read out with a Ge thermi…
Reconstruction of cosmic-ray muon events with CUORE
CUORE Collaboration, D. Q. Adams, C. Alduino +118
We report the in-situ 3D reconstruction of through-going muons in the CUORE experiment, a cryogenic calorimeter array searching for neutrinoless double beta () decay, leverag…
Description of CRESST-II and CRESST-III pulse shape data
G. Angloher, S. Banik, D. Bartolot +62
A set of data from 68 cryogenic detectors operated in the CRESST dark matter search experiment between 2013 and 2019 was collected and labeled to train binary classifiers for data…
Observation of a low energy nuclear recoil peak in the neutron calibration data of an AlO crystal in CRESST-III
CRESST Collaboration, G. Angloher, S. Banik +59
The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of (10)eV for nucl…
Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source
H. Abele, G. Angloher, B. Arnold +61
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on…
The detection of marine microseismic activity with the CUORE tonne-scale cryogenic experiment
D. Q. Adams, C. Alduino, K. Alfonso +126
Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double b…
Innovating Bolometers' Mounting: A Gravity-Based Approach
The CUPID Collaboration, K. Alfonso, A. Armatol +190
Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a t…
CUPID, the CUORE Upgrade with Particle IDentification
The CUPID Collaboration, K. Alfonso, A. Armatol +190
CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay () and other rare events using enriched Li…
A new dark matter direct search based on archaeological Pb
D. Alloni, G. Benato, P. Carniti +44
The RES-NOVA project is an experimental initiative aimed at detecting neutrinos from the next galactic supernova using PbWO cryogenic detectors, operated at low temperatures…
Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures
The NUCLEUS collaboration, A. Wex, J. Rothe +64
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems…
DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes
G. Angloher, S. Banik, G. Benato +55
In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known a…
Detector development for the CRESST experiment
G. Angloher, S. Banik, G. Benato +55
Recently low-mass dark matter direct searches have been hindered by a low energy background, drastically reducing the physics reach of the experiments. In the CRESST-III experiment…
A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures
A. Erhart, V. Wagner, A. Wex +59
Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon ve…
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
G. Angloher, S. Banik, G. Benato +59
Using CaWO crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identi…
Study of collision and -cascade times following neutron-capture processes in cryogenic detectors
CRAB collaboration, G. Soum-Sidikov, H. Abele +47
The emission of -rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration o…
A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat
CUPID collaboration, K. Alfonso, A. Armatol +176
CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of Mo. It will operate at 10 mK…
Twelve-crystal prototype of LiMoO scintillating bolometers for CUPID and CROSS experiments
CUPID, CROSS collaborations, : +182
An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS…
Observation of a low energy nuclear recoil peak in the neutron calibration data of the CRESST-III Experiment
CRESST Collaboration, G. Angloher, S. Banik +58
New-generation direct searches for low mass dark matter feature detection thresholds at energies well below 100 eV, much lower than the energies of commonly used X-ray calibration…
Exploring coherent elastic neutrino-nucleus scattering of reactor neutrinos with the NUCLEUS experiment
The NUCLEUS collaboration, C. Goupy, H. Abele +59
The NUCLEUS experiment aims to perform a high-precision measurement of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) at the EdF Chooz B nuclear power plant in France. CEvNS…
Towards an automated data cleaning with deep learning in CRESST
G. Angloher, S. Banik, D. Bartolot +62
The CRESST experiment employs cryogenic calorimeters for the sensitive measurement of nuclear recoils induced by dark matter particles. The recorded signals need to undergo a caref…
Secular Equilibrium Assessment in a Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation
G. Angloher, S. Banik, G. Benato +58
CRESST is a leading direct detection sub- dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\ma…
Characterization of a kg-scale archaeological lead-based cryogenic detectors for the RES-NOVA experiment
J. W. Beeman, G. Benato, C. Bucci +41
One of the most energetic events in the Universe are core-collapse Supernovae (SNe), where almost all the star's binding energy is released as neutrinos. These particles are direct…