activity
20092024
most citedTitanium Nitride Films for Ultrasensitive Microresonator Detectors

245 citations · 691 across the 17 of their papers we have counts for

collaborators

17 papers

astro-ph.IM2024★ 2 cited

Superfluid-tight cryogenic receiver with continuous sub-Kelvin cooling for EXCLAIM

Sumit Dahal, Peter A. R. Ade, Christopher J. Anderson +67

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity…

astro-ph.IM2023★ 1 cited

Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers

Maryam Rahmani, Emily M. Barrentine, Eric R. Switzer +19

We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity…

astro-ph.IM2022

Optical Characterization & Testbed Development for μ-Spec Integrated Spectrometers

Maryam Rahmani, Alyssa Barlis, Emily M. Barrentine +21

This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrate…

astro-ph.IM2022

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

Carolyn G. Volpert, Emily M. Barrentine, Mona Mirzaei +21

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of th…

astro-ph.IM2022

Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors

Trevor M. Oxholm, Eric R. Switzer, Emily M. Barrentine +11

Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude bal…

hep-ex2022★ 56 cited

New Horizons: Scalar and Vector Ultralight Dark Matter

D. Antypas, A. Banerjee, C. Bartram +123

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances…

cond-mat.supr-con2022

Dual-Resonator Kinetic-Inductance Detector for Distinction between Signal and 1/f Frequency Noise

N. Foroozani, B. Sarabi, S. H. Moseley +4

Astronomical Kinetic Inductance Detectors (KIDs), similar to quantum information devices, experience performance limiting noise from materials. In particular, 1/f (frequency) noise…

physics.ins-det2021★ 143 cited

Broadband solenoidal haloscope for terahertz axion detection

Jesse Liu, Kristin Dona, Gabe Hoshino +18

We introduce the Broadband Reflector Experiment for Axion Detection (BREAD) conceptual design and science program. This haloscope plans to search for bosonic dark matter across the…

astro-ph.IM2021★ 7 cited

μ-Spec Spectrometers for the EXCLAIM Instrument

Mona Mirzaei, Emily M. Barrentine, Berhanu T. Bulcha +12

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lin…

astro-ph.IM2021★ 6 cited

Overview and status of EXCLAIM, the experiment for cryogenic large-aperture intensity mapping

Giuseppe Cataldo, Peter Ade, Christopher Anderson +41

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne far-infrared telescope that will survey star formation history over cosmological time sca…

astro-ph.IM2019★ 30 cited

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

P. A. R. Ade, C. J. Anderson, E. M. Barrentine +33

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological…

astro-ph.GA2019★ 1 cited

The case for a 'sub-millimeter SDSS': a 3D map of galaxy evolution to z~10

James E. Geach, Manda Banerji, Frank Bertoldi +53

The Sloan Digital Sky Survey (SDSS) was revolutionary because of the extraordinary breadth and ambition of its optical imaging and spectroscopy. We argue that a 'sub-millimeter SDS…

astro-ph.CO2015★ 25 cited

Peculiar Velocity Constraints from Five-Band SZ Effect Measurements Towards RX J1347.5-1145 with MUSIC and Bolocam from the CSO

Jack Sayers, Michael Zemcov, Jason Glenn +25

We present Sunyaev-Zel'dovich (SZ) effect measurements from wide-field images towards the galaxy cluster RX J1347.5-1145 obtained from the Caltech Submillimeter Observatory with th…

physics.ins-det2013★ 69 cited

High-resolution gamma-ray spectroscopy with a microwave-multiplexed transition-edge sensor array

Omid Noroozian, John A. B. Mates, Douglas A. Bennett +10

We demonstrate very high resolution photon spectroscopy with a microwave-multiplexed two-pixel transition-edge sensor (TES) array. We measured a Gd photon source and achiev…

astro-ph.IM2012★ 40 cited

Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera

Sunil R. Golwala, Clint Bockstiegel, Spencer Brugger +21

We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', d…

cond-mat.supr-con2010★ 245 cited

Titanium Nitride Films for Ultrasensitive Microresonator Detectors

Henry G. Leduc, Bruce Bumble, Peter K. Day +10

Titanium nitride (TiNx) films are ideal for use in superconducting microresonator detectors because: a) the critical temperature varies with composition (0 < Tc < 5 K); b) the norm…

physics.ins-det2009★ 66 cited

Two-level system noise reduction for Microwave Kinetic Inductance Detectors

Omid Noroozian, Jiansong Gao, Jonas Zmuidzinas +2

Noise performance is one of the most crucial aspects of any detector. Superconducting Microwave Kinetic Inductance Detectors (MKIDs) have an "excess" frequency noise that shows up…