activity
20012026
most citedThe Simons Observatory: Science goals and forecasts

1.5k citations · 5.8k across the 146 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

46 papers · 1 filter

physics.ins-det2026

Development of microwave multiplexed readout for athermal phonon TES-based detectors

Tran Tsan, Douglas A. Bennett, Daniel T. Becker +6

Continued advancements in sub-eV calorimetric measurements are being enabled through the athermal phonon detection channel, with applications spanning a diverse array of fields, in…

physics.ins-det2026

Nuclear Data Needs for Microcalorimetry and Non-destructive Assay

Geon-Bo Kim, Begona Aranguren-Barrado, Shamsuzzoha Basunia +5

Cryogenic microcalorimeters are state-of-the-art radiation detectors using superconducting and quantum technologies. They can resolve complex X-ray and low-energy γ-ray spectra wit…

physics.ins-det2026

Characterization of Silicon-Membrane TES Microcalorimeters for Large-Format X-ray Spectrometers with Integrated Microwave SQUID Readout

Avirup Roy, Robinjeet Singh, Joel C. Weber +17

We present the electro-thermal characterization of transition-edge sensor (TES) detectors suspended on Si membranes fabricated using a silicon-on-insulator (SOI) wafer. The use of…

physics.ins-det2025

Lithographic integration of TES microcalorimeters with SQUID multiplexer circuits for large format spectrometers

Robinjeet Singh, Avirup Roy, Daniel Becker +12

Arrays of hundreds or thousands of low temperature detectors have been deployed for many experiments, both bolometers for long wavelength applications and calorimeters for shorter…

physics.ins-det2025

Detecting and Correcting Gain Jumps in TES Microcalorimeters

Thomas A. Baker, Daniel T. Becker, Joseph W. Fowler +3

Arrays of microcalorimeters based on transition-edge sensors (TESs) are being actively deployed to laboratories all over the world. A TES microcalorimeter array produces very large…

physics.ins-det2025★ 5 cited

Demonstration of a 1820 channel multiplexer for transition-edge sensor bolometers

J. C. Groh, Z. Ahmed, J. Austermann +16

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this…

physics.ins-det2024★ 17 cited

Kinetic inductance current sensor for visible to near-infrared wavelength transition-edge sensor readout

Paul Szypryt, Douglas A. Bennett, Ian Fogarty Florang +12

Single-photon detectors based on the superconducting transition-edge sensor are used in a number of visible to near-infrared applications, particularly for photon-number-resolving…

physics.ins-det2022★ 12 cited

A tabletop x-ray tomography instrument for nanometer-scale imaging: demonstration of the 1,000-element transition-edge sensor subarray

Paul Szypryt, Nathan Nakamura, Daniel T. Becker +28

We report on the 1,000-element transition-edge sensor (TES) x-ray spectrometer implementation of the TOMographic Circuit Analysis Tool (TOMCAT). TOMCAT combines a high spatial reso…

physics.ins-det2022★ 18 cited

Design of a 3000-pixel transition-edge sensor x-ray spectrometer for microcircuit tomography

Paul Szypryt, Douglas A. Bennett, William J. Boone +28

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabr…

physics.ins-det2022★ 3 cited

Nanoscale Three-Dimensional Imaging of Integrated Circuits using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

Nathan Nakamura, Paul Szypryt, Amber L. Dagel +30

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but is difficult to implement due to competing requirements on X-ray flux an…

physics.ins-det2022★ 39 cited

SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Cyndia Yu, Zeeshan Ahmed, Josef C. Frisch +22

We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic det…

physics.ins-det2022★ 1 cited

The potential of microcalorimeter x-ray spectrometers for measurement of relative fluorescence-line intensities

J. W. Fowler, L. Miaja-Avila, G. C. O'Neil +3

We have previously used an array of cryogenic microcalorimeters with 4 eV energy resolution to measure emission-line profiles and energies of the characteristic L-shell x rays of f…

physics.ins-det2022★ 2 cited

Absolute Energy Measurements with Superconducting Transition-Edge Sensors for Muonic X-ray Spectroscopy at 44 keV

Daikang Yan, Joel C. Weber, Tejas Guruswamy +25

Superconducting transition-edge sensor (TES) microcalorimeters have great utility in x-ray applications owing to their high energy resolution, good collecting efficiency and the fe…

physics.ins-det2022★ 4 cited

Bandwidth and Aliasing in the Microwave SQUID Multiplexer

Cyndia Yu, Zeeshan Ahmed, Jake A. Connors +13

The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. Th…

physics.ins-det2022★ 6 cited

Energy calibration of nonlinear microcalorimeters with uncertainty estimates from Gaussian process regression

J. W. Fowler, B. K. Alpert, G. C. O'Neil +2

The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anch…

physics.ins-det2022★ 2 cited

Quantification of 242Pu with a Microcalorimeter Gamma Spectrometer

David J. Mercer, Ryan Winkler, Katrina E. Koehler +18

We report measurements of the 103-keV and 159-keV gamma ray signatures of 242Pu using microcalorimetry. This is the first observation of these gamma rays in a non-destructive measu…

physics.ins-det2021★ 1 cited

Improved Nondestructive Isotopic Analysis with Practical Microcalorimeter Gamma Spectrometers

Mark Croce, Daniel Becker, Katrina E. Koehler +1

Advances in both instrumentation and data analysis software are now enabling the first ultra-high-resolution microcalorimeter gamma spectrometers designed for implementation in nuc…

physics.ins-det2021★ 1 cited

First Measurements of Nuclear Detonation Debris with Decay Energy Spectroscopy

Mark P. Croce, Katrina E. Koehler, Veronika Mocko +4

We report the first isotopic composition measurements of trinitite, nuclear detonation debris from the Trinity test, using the novel forensics technique of decay energy spectroscop…

physics.ins-det2021★ 10 cited

Progress in the development of TES microcalorimeter detectors suitable for neutrino mass measurement

A. Giachero, B. Alpert, D. T. Becker +19

The HOLMES experiment will perform a precise calorimetric measurement of the end point of the Electron Capture (EC) decay spectrum of 163Ho in order to extract information on neutr…

physics.ins-det2020★ 17 cited

Absolute energies and emission line shapes of the L x-ray transitions of lanthanide metals

Joseph W. Fowler, Galen C. O'Neil, Bradley K. Alpert +11

We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide se…

physics.ins-det2020★ 39 cited

A Transition-edge Sensor-based X-ray Spectrometer for the Study of Highly Charged Ions at the National Institute of Standards and Technology Electron Beam Ion Trap

P. Szypryt, G. C. O'Neil, E. Takacs +15

We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institut…

physics.ins-det2020★ 10 cited

On low-energy tail distortions in the detector responsefunction of x-ray microcalorimeter spectrometers

G. C. O'Neil, P. Szypryt, E. Takacs +12

We use narrow spectral lines from the x-ray spectra of various highlycharged ions to measure low-energy tail-like deviations from a Gaussian responsefunction in a microcalorimter x…

physics.ins-det2019★ 25 cited

Working principle and demonstrator of microwave-multiplexing for the HOLMES experiment microcalorimeters

D. T. Becker, D. A. Bennett, M. Biasotti +21

The determination of the neutrino mass is an open issue in modern particle physics and astrophysics. The direct mass measurement is the only theory-unrelated experimental tool capa…

physics.ins-det2019★ 5 cited

Mitigating the effects of charged particle strikes on TES arrays for exotic atom X-ray experiments

H. Tatsuno, D. A. Bennett, W. B. Doriese +16

Exotic atom experiments place transition-edge-sensor (TES) microcalorimeter arrays in a high-energy charged particle rich environment. When a high-energy charged particle passes th…