Broad-band High-Energy Resolution Hard X-ray Spectroscopy using Transition Edge Sensors at SPring-8
Shinya Yamada, Yuto Ichinohe, Hideyuki Tatsuno +40
We have succeeded in operating a transition-edge sensor (TES) spectrometer and evaluating its performance at the SPring-8 synchrotron X-ray light source. The TES spectrometer consi…
Improved microwave SQUID multiplexer readout using a kinetic-inductance traveling-wave parametric amplifier
M. Malnou, J. A. B. Mates, M. R. Vissers +5
We report on the use of a kinetic-inductance traveling-wave parametric amplifier (KITWPA) as the first amplifier in the readout chain of a microwave superconducting quantum interfe…
ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors
Fabian Kislat, Daniel Becker, Douglas Bennett +26
Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to o…
Line Emission Mapper (LEM): Probing the physics of cosmic ecosystems
Ralph Kraft, Maxim Markevitch, Caroline Kilbourne +107
The Line Emission Mapper (LEM) is an X-ray Probe for the 2030s that will answer the outstanding questions of the Universe's structure formation. It will also provide transformative…
The 511-CAM Mission: A Pointed 511 keV Gamma-Ray Telescope with a Focal Plane Detector Made of Stacked Transition Edge Sensor Microcalorimeter Arrays
Farzane Shirazi, Md. Arman Hossen, Daniel Becker +18
The 511 keV gamma-ray emission from the galactic center region may fully or partially originate from the annihilation of positrons from dark matter particles with electrons from th…
A Microwave SQUID Multiplexer Optimized for Bolometric Applications
B. Dober, Z. Ahmed, K. Arnold +27
A microwave SQUID multiplexer (MUX) has been optimized for coupling to large arrays of superconducting transition-edge sensor (TES) bolometers. We present the scalable cryogenic…
Highly-multiplexed microwave SQUID readout using the SLAC Microresonator Radio Frequency (SMuRF) Electronics for Future CMB and Sub-millimeter Surveys
Shawn W. Henderson, Zeeshan Ahmed, Jason Austermann +29
The next generation of cryogenic CMB and submillimeter cameras under development require densely instrumented sensor arrays to meet their science goals. The readout of large number…
Microwave SQUID Multiplexer demonstration for Cosmic Microwave Background Imagers
B. Dober, D. T. Becker, D. A. Bennett +10
Key performance characteristics are demonstrated for the microwave SQUID multiplexer (MUX) coupled to transition edge sensor (TES) bolometers that have been optimized for cosmic…