437 citations · 2.4k across the 38 of their papers we have counts for
20 papers · 1 filter
EXO-200 Public Data Release for AI/ML Applications
S. Al Kharusi, G. Anton, I. Badhrees +103
We present a public release of a subset of calibration data from the EXO-200 experiment, a liquid xenon time projection chamber designed to search for neutrinoless double-beta deca…
Design of a high voltage delivery system for noble liquid time projection chambers
R. Saldanha, L. Pagani, E. Angelico +129
Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dar…
The EXO-200 detector, part II: Auxiliary Systems
N. Ackerman, J. Albert, M. Auger +157
The EXO-200 experiment searched for neutrinoless double-beta decay of Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liqui…
Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment
200 Collaboration, G. Anton, I. Badhrees +99
Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and i…
GEANT4 models of HPGe detectors for radioassay
R. H. M. Tsang, A. Piepke, D. J. Auty +7
Radiation transport models of two high purity germanium detectors, GeII and GeIII, located at the University of Alabama have been created in GEANT4 \cite{geant4}. These detectors h…
Study of Silicon Photomultiplier Performance in External Electric Fields
X. L. Sun, T. Tolba, G. F. Cao +149
We report on the performance of silicon photomultiplier (SiPM) light sensors operating in electric field strength up to 30 kV/cm and at a temperature of 149K, relative to their per…
VUV-sensitive Silicon Photomultipliers for Xenon Scintillation Light Detection in nEXO
A. Jamil, T. Ziegler, P. Hufschmidt +140
Future tonne-scale liquefied noble gas detectors depend on efficient light detection in the VUV range. In the past years Silicon Photomultipliers (SiPMs) have emerged as a valid al…
nEXO Pre-Conceptual Design Report
nEXO Collaboration, S. Al Kharusi, A. Alamre +171
The projected performance and detector configuration of nEXO are described in this pre-Conceptual Design Report (pCDR). nEXO is a tonne-scale neutrinoless double beta () deca…
Deep Neural Networks for Energy and Position Reconstruction in EXO-200
S. Delaquis, M. J. Jewell, I. Ostrovskiy +91
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position -…
Characterization of an Ionization Readout Tile for nEXO
nEXO Collaboration, M. Jewell, A. Schubert +142
A new design for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produce…
Trace radioactive impurities in final construction materials for EXO-200
D. S. Leonard, D. Auty, T. Didberidze +98
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial…
Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector
200 Collaboration, J. B. Albert, P. S. Barbeau +84
The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of c…
An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout
200 Collaboration, C. G. Davis, C. Hall +84
The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal s…
Investigation of radioactivity-induced backgrounds in EXO-200
J. B. Albert, D. J. Auty, P. S. Barbeau +83
The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of pa…
An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe
K. Twelker, S. Kravitz, M. Montero Díez +77
We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to…
A light readout system for gas TPCs
G. Giroux, M. Auger, D. Franco +6
A novel light detection scheme has been tested for use in medium-pressure gas TPCs, in view of rare events searches in low energy particle physics. It has the advantage of minimal…
Development of a camera casing suited for cryogenic and vacuum applications
S. C. Delaquis, R. Gornea, S. Janos +4
We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a li…
Pulse-shape discrimination of scintillation from alpha and beta particles with liquid scintillator and Geiger-mode multipixel avalanche diodes
I. Kreslo, I. Badhrees, S. Delaquis +6
A successfull application of Geiger-mode multipixel avalanche diodes (GMAPDs) for pulse-shape discrimination in alpha-beta spectrometry using organic liquid scintillator is describ…
30 kV coaxial vacuum-tight feedthrough for operation at cryogenic temperatures
I. Kreslo, I. Badhrees, S. Delaquis +6
In this paper we describe the technology of building a vacuum-tight high voltage feedthrough which is able to operate at voltages up to 30 kV. The feedthrough has a coaxial structu…
Ionization signals from electrons and alpha-particles in mixtures of liquid Argon and Nitrogen - perspectives on protons for Gamma Resonant Nuclear Absorption applications
M. Zeller, I. Badhrees, S. Delaquis +6
In this paper we report on a detailed study of ionization signals produced by Compton electrons and alpha-particles in a Time Projection Chamber (TPC) flled with different mixtures…