activity
20102023
most citedNeutrino Physics with JUNO

1.2k citations · 1.7k across the 26 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

17 papers · 1 filter

physics.ins-det2022★ 64 cited

Mass Testing and Characterization of 20-inch PMTs for JUNO

Angel Abusleme, Thomas Adam, Shakeel Ahmad +556

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least…

physics.ins-det2021★ 8 cited

Development of water extraction system for liquid scintillatorpurification of JUNO

Jiaxuan Ye, Jian Fang, Tao hu +10

The Jiangmen Underground Neutrino Observatory (JUNO) uses 20k tons of liquid scintillator (LS)to detect neutrinos. The content of radioactive substances in the liquid scintillator…

physics.ins-det2021★ 35 cited

Radioactivity control strategy for the JUNO detector

JUNO collaboration, Angel Abusleme, Thomas Adam +594

JUNO is a massive liquid scintillator detector with a primary scientific goal of determining the neutrino mass ordering by studying the oscillated anti-neutrino flux coming from tw…

physics.ins-det2021

The Design and Sensitivity of JUNO's scintillator radiopurity pre-detector OSIRIS

JUNO Collaboration, Angel Abusleme, Thomas Adam +598

The OSIRIS detector is a subsystem of the liquid scintillator fillling chain of the JUNO reactor neutrino experiment. Its purpose is to validate the radiopurity of the scintillator…

physics.ins-det2020★ 2 cited

The replacement system of the JUNO liquid scintillator pilot experiment at Daya Bay

Wenqi Yan, Tao Hu, Li Zhou +13

The Jiangmen Underground Neutrino Observatory (JUNO), a multi-purpose neutrino experiment, will use 20 kt liquid scintillator (LS). To achieve the physics goal of determining the n…

physics.ins-det2020★ 70 cited

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

JUNO Collaboration, Angel Abusleme, Thomas Adam +585

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillato…

physics.ins-det2016★ 5 cited

The laboratory measurement of radioactivity purification for Pb212 in liquid scintillator

Wei Hu, Jian Fang, Boxiang Yu +7

The liquid scintillator (LS) has been widely utilized in the past, running and future neutrino experiments, and requirement to the LS radio-purity is higher and higher. The water e…

physics.ins-det2015★ 13 cited

Upgrade of Beam Energy Measurement System at BEPC-II

Jian-Yong Zhang, Xiao Cai, Xiao-Hu Mo +9

The beam energy measurement system is of great importance and profit for both BEPC-II accelerator and BES-III detector. The system is based on measuring the energies of Compton bac…

physics.ins-det2015★ 1.2k cited

Neutrino Physics with JUNO

Fengpeng An, Guangpeng An, Qi An +224

The Jiangmen Underground Neutrino Observatory (JUNO), a 20 kton multi-purpose underground liquid scintillator detector, was proposed with the determination of the neutrino mass hie…

physics.ins-det2014★ 13 cited

Simulation of background reduction and Compton depression in low-background HPGe spectrometer at a surface laboratory

ShunLi Niu, Xiao Cai, ZhenZhong Wu +13

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper…

physics.ins-det2014★ 2 cited

Simulation and performance study of the ceramic THGEM

Jia-Qing Yan, Yu-Guang Xie, Tao Hu +6

The THGEMs based on ceramic substrate were developed successfully for neutron and single photon detection. The influences on thermal neutron scattering and the internal radioactivi…

physics.ins-det2014

CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy

D. R. Artusa, F. T. Avignone, O. Azzolini +117

The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of Te. With 741 kg of TeO crystals and an excell…

physics.ins-det2013★ 19 cited

Attenuation length measurements of liquid scintillator with LabVIEW and reliability evaluation of the device

L. Gao, BX. Yu, YY. Ding +17

The attenuation length measuring device was constructed by using oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested with…

physics.ins-det2011★ 10 cited

Experimental study of THGEM detector with mini-rim

Ai-Wu Zhang, Bo-Xiang Yu, Yu-Guang Xie +15

The gas gain and energy resolution of single and double THGEM detectors (5{\times}5cm2 effective area) with mini-rims (rim is less than 10μm) were studied. The maximum gain can rea…

physics.ins-det2011★ 14 cited

The fast light of CsI(Na) crystals

Xilei Sun, Junguang Lu, Tao Hu +16

The responds of different common alkali halide crystals to alpha-rays and gamma-rays are tested in our research. It is found that only CsI(Na) crystals have significantly different…

physics.ins-det2011★ 19 cited

Neutron-gamma discrimination of CsI(Na) crystals for dark matter searches

Xilei Sun, Junguang Lu, Tao Hu +15

The luminescent properties of CsI(Na) crystals are studied in this report. By using a TDS3054C oscilloscope with a sampling frequency of 5 GS/s, we find out that nuclear recoil sig…

physics.ins-det2010

Architecture of a Silicon Strip Beam Position Monitor

R. Angstadt, W. Cooper, M. Demarteau +7

A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is…