activity
20052026
most citedImproved search for muon-neutrino to electron-neutrino oscillations in MINOS

696 citations · 8.9k across the 101 of their papers we have counts for

collaborators
Showing physics.ins-detShow all

18 papers · 1 filter

physics.ins-det2020★ 23 cited

Supernova neutrino detection in NOvA

NOvA Collaboration, M. A. Acero, P. Adamson +199

The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Ferm…

physics.ins-det2020★ 28 cited

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

R. Acciarri, C. Adams, C. Andreopoulos +192

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assemble…

physics.ins-det2019★ 29 cited

The Liquid Argon In A Testbeam (LArIAT) Experiment

LArIAT Collaboration, R. Acciarri, C. J. Adams +103

The LArIAT liquid argon time projection chamber, placed in a tertiary beam of charged particles at the Fermilab Test Beam Facility, has collected large samples of pions, muons, ele…

physics.ins-det2019★ 38 cited

Calorimetry for low-energy electrons using charge and light in liquid argon

W. Foreman, R. Acciarri, J. A. Asaadi +60

Precise calorimetric reconstruction of 5-50 MeV electrons in liquid argon time projection chambers (LArTPCs) will enable the study of astrophysical neutrinos in DUNE and could enha…

physics.ins-det2019★ 15 cited

Observation of seasonal variation of atmospheric multiple-muon events in the NOvA Near Detector

M. A. Acero, P. Adamson, L. Aliaga +188

Using two years of data from the NOvA Near Detector at Fermilab, we report a seasonal variation of cosmic ray induced multiple-muon event rates which has an opposite phase to the s…

physics.ins-det2017★ 429 cited

Design and Construction of the MicroBooNE Detector

MicroBooNE Collaboration, R. Acciarri, C. Adams +237

This paper describes the design and construction of the MicroBooNE liquid argon time projection chamber and associated systems. MicroBooNE is the first phase of the Short Baseline…

physics.ins-det2015★ 10 cited

Design and operation of LongBo: a 2 m long drift liquid argon TPC

C. Bromberg, B. Carls, D. Edmunds +12

In this paper, we report on the design and operation of the LongBo time projection chamber in the Liquid Argon Purity Demonstrator cryostat. This chamber features a 2 m long drift…

physics.ins-det2015★ 13 cited

Summary of the Second Workshop on Liquid Argon Time Projection Chamber Research and Development in the United States

R. Acciarri, M. Adamowski, D. Artrip +41

The second workshop to discuss the development of liquid argon time projection chambers (LArTPCs) in the United States was held at Fermilab on July 8-9, 2014. The workshop was orga…

physics.ins-det2015★ 302 cited

A Proposal for a Three Detector Short-Baseline Neutrino Oscillation Program in the Fermilab Booster Neutrino Beam

R. Acciarri, C. Adams, R. An +221

A Short-Baseline Neutrino (SBN) physics program of three LAr-TPC detectors located along the Booster Neutrino Beam (BNB) at Fermilab is presented. This new SBN Program will deliver…

physics.ins-det2014★ 18 cited

Liquid Argon Dielectric Breakdown Studies with the MicroBooNE Purification System

R. Acciarri, B. Carls, C. James +9

The proliferation of liquid argon time projection chamber detectors makes the characterization of the dielectric properties of liquid argon a critical task. To improve understandin…

physics.ins-det2014★ 25 cited

LArIAT: Liquid Argon In A Testbeam

J. Paley, D. Gastler, E. Kearns +64

Liquid Argon Time Projection Chambers (LArTPCs) are ideal detectors for precision neutrino physics. These detectors, when located deep underground, can also be used for measurement…

physics.ins-det2014★ 45 cited

The Liquid Argon Purity Demonstrator

M. Adamowski, B. Carls, E. Dvorak +15

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first e…

physics.ins-det2014★ 18 cited

High Voltage in Noble Liquids for High Energy Physics

Edited by B. Rebel, C. Hall with contributions from E. Bernard, C. H. Faham +12

A workshop was held at Fermilab November 8-9, 2013 to discuss the challenges of using high voltage in noble liquids. The participants spanned the fields of neutrino, dark matter, a…

physics.ins-det2013★ 14 cited

Liquid Argon Time Projection Chamber Research and Development in the United States

B. Baller, C. Bromberg, N. Buchanan +34

A workshop was held at Fermilab on March 20-21, 2013 to discuss the development of liquid argon time projection chambers (LArTPC) in the United States. The workshop was organized u…

physics.ins-det2013★ 109 cited

A study of electron recombination using highly ionizing particles in the ArgoNeuT Liquid Argon TPC

R. Acciarri, C. Adams, J. Asaadi +29

Electron recombination in highly ionizing stopping protons and deuterons is studied in the ArgoNeuT detector. The data are well modeled by either a Birks model or a modified form o…

physics.ins-det2012★ 161 cited

The ArgoNeuT Detector in the NuMI Low-Energy beam line at Fermilab

C. Anderson, M. Antonello, B. Baller +35

The ArgoNeuT liquid argon time projection chamber has collected thousands of neutrino and antineutrino events during an extended run period in the NuMI beam-line at Fermilab. This…

physics.ins-det2012★ 21 cited

Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector

C. Anderson, M. Antonello, B. Baller +31

ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Lab…

physics.ins-det2008★ 314 cited

The magnetized steel and scintillator calorimeters of the MINOS experiment

MINOS Collaboration, D. G. Michael

The Main Injector Neutrino Oscillation Search (MINOS) experiment uses an accelerator-produced neutrino beam to perform precision measurements of the neutrino oscillation parameters…