462 citations · 4.4k across the 27 of their papers we have counts for
20 papers · 1 filter
A new experiment to test parity symmetry in cold chiral molecules using vibrational spectroscopy
A Cournol, M. Manceau, M. Pierens +21
We present a brief review of our progress towards measuring parity violation in heavy-metal chiral complexes using mid-infrared Ramsey interferometry. We discuss our progress addre…
High-precision methanol spectroscopy with a widely tunable SI-traceable frequency-comb-based mid-infrared QCL
R. Santagata, D. Tran, B. Argence +14
There is an increasing demand for precise molecular spectroscopy, in particular in the mid-infrared fingerprint window that hosts a considerable number of vibrational signatures, w…
New measurement of the transition frequency of hydrogen: contribution to the proton charge radius puzzle
Hélène Fleurbaey, Sandrine Galtier, Simon Thomas +6
We present a new measurement of the two-photon transition frequency of hydrogen, realized with a continuous-wave excitation laser at 205 nm on a room-temperature atomic bea…
First international comparison of fountain primary frequency standards via a long distance optical fiber link
J. Guéna, S. Weyers, M. Abgrall +25
We report on the first comparison of distant caesium fountain primary frequency standards (PFSs) via an optical fiber link. The 1415 km long optical link connects two PFSs at LNE-S…
Optical to microwave clock frequency ratios with a nearly continuous strontium optical lattice clock
Jérôme Lodewyck, Sławomir Bilicki, Eva Bookjans +10
Optical lattice clocks are at the forefront of frequency metrology. Both the instability and systematic uncertainty of these clocks have been reported to be two orders of magnitude…
Comparing a mercury optical lattice clock with microwave and optical frequency standards
R Tyumenev, M Favier, S Bilicki +9
In this paper we report the evaluation of an optical lattice clock based on neutral mercury down to a relative uncertainty of . Comparing this characterized fre…
A clock network for geodesy and fundamental science
C. Lisdat, G. Grosche, N. Quintin +32
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the fr…
Atomic fountains and optical clocks at SYRTE: status and perspectives
M. Abgrall, B. Chupin, L. De Sarlo +9
In this article, we report on the work done with the LNE-SYRTE atomic clock ensemble during the last 10 years. We cover progress made in atomic fountains and in their application t…
Contributing to TAI with a Secondary Representation of the SI Second
Jocelyne Guéna, Michel Abgrall, André Clairon +1
We report the first contribution to the international atomic time (TAI) based on a secondary representation of the SI second. This work is done with the LNE-SYRTE FO2-Rb fountain f…
Demonstration of a Dual Alkali Rb/Cs Atomic Fountain Clock
J. Guéna, P. Rosenbusch, Ph. Laurent +7
We report the operation of a dual Rb/Cs atomic fountain clock. 133Cs and 87Rb atoms are cooled, launched, and detected simultaneously in LNE-SYRTE's FO2 double fountain. The dual c…
Experimenting an optical second with strontium lattice clocks
R. Le Targat, L. Lorini, Y. Le Coq +17
Progress in realizing the SI second had multiple technological impacts and enabled to further constraint theoretical models in fundamental physics. Caesium microwave fountains, rea…
Improved tests of Local Position Invariance using 87Rb and 133Cs fountains
Jocelyne Guéna, Michel Abgrall, Daniele Rovera +5
We report tests of local position invariance based on measurements of the ratio of the ground state hyperfine frequencies of 133Cs and 87Rb in laser-cooled atomic fountain clocks.…
Progress in Atomic Fountains at LNE-SYRTE
Jocelyne Guéna, Michel Abgrall, Daniele Rovera +10
We give an overview of the work done with the Laboratoire National de Métrologie et d'Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five y…
Improved Measurement of the Hydrogen 1S - 2S Transition Frequency
Christian G. Parthey, Arthur Matveev, Janis Alnis +14
We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain Hz for t…
Ultra-low noise microwave generation with fiber-based optical frequency comb and application to atomic fountain clock
J. Millo, M. Abgrall, M. Lours +8
We demonstrate the use of a fiber-based femtosecond laser locked onto an ultra-stable optical cavity to generate a low-noise microwave reference signal. Comparison with both a liqu…
Absolute frequency measurement of the 40Ca+ S1/2 - D5/2 clock transition
M. Chwalla, J. Benhelm, K. Kim +12
We report on the first absolute transition frequency measurement at the 10^{-15} level with a single, laser-cooled 40Ca+ ion in a linear Paul trap. For this measurement, a frequenc…
An Optical Lattice Clock with Spin-polarized 87Sr Atoms
Xavier Baillard, Mathilde Fouché, Rodolphe Le Targat +14
We present a new evaluation of an 87Sr optical lattice clock using spin polarized atoms. The frequency of the 1S0-3P0 clock transition is found to be 429 228 004 229 873.6 Hz with…
Cold atom Clocks and Applications
S. Bize, P. Laurent, M. Abgrall +14
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the Cs and Rb atomic fountains ar…
Precision Spectroscopy of Atomic Hydrogen and Variations of Fundamental Constants
M. Fischer, N. Kolachevsky, M. Zimmermann +14
In 2003 we have measured the absolute frequency of the two-photon transition in atomic hydrogen. We observed a variati…
A Search for Variations of Fundamental Constants using Atomic Fountain Clocks
H. Marion, F. Pereira Dos Santos, M. Abgrall +12
Over five years we have compared the hyperfine frequencies of 133Cs and 87Rb atoms in their electronic ground state using several laser cooled 133Cs and 87Rb atomic fountains with…