4 citations · 10 across the 15 of their papers we have counts for
19 papers
Optical readout of MPGDs with solid wavelength shifters
F. M. Brunbauer, A. Cools, M. Cortesi +20
Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle…
Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with active area
A. Pandey, K. Gnanvo, B. Kross +60
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and…
Advances in photocathode development for PICOSEC Micromegas precise-timing detectors
M. Lisowska, F. Guerra, A. Gurpinar +46
The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targe…
Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
F. M. Brunbauer, R. Aleksan, Y. Angelis +47
The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolu…
μRWELL-PICOSEC: Precision Timing with Resistive Micro-Well Detector
Kondo Gnanvo
The PICOSEC detector concept uses a micro-pattern gaseous detector (MPGD) amplification structure combined with a Cerenkov radiator coated with a semi-transparent photocathode to p…
Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET
A. Kallitsopoulou, S. Aune, Y. Angelis +54
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micr…
Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors
A. Kallitsopoulou, R. Aleksan, S. Aune +49
We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and ph…
Measurements of enriched 155 Gd and 157Gd converters with the NMX detector on the nTOF EAR2 beam line at CERN
D. Pfeiffer, F. M. Brunbauer, I. R. Fehse +15
The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of…
Embedding the Timepix4 in Micro-Pattern Gaseous Detectors
L. Scharenberg, J. Alozy, W. Billereau +27
The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous…
PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration
Y. Meng, R. Aleksan, Y. Angelis +49
PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector…
The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout
F. Garcia, K. J. Flöthner, A. Amato +21
The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in differen…
Towards MPGDs with embedded pixel ASICs
L. Scharenberg, J. Alozy, W. Billereau +27
Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution…
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
A. Kallitsopoulou, R. Aleksan, Y. Angelis +49
The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged…
A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors
X. Wang, R. Aleksan, Y. Angelis +48
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes eq…
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
M. Lisowska, R. Aleksan, Y. Angelis +55
The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structur…
Spatial resolution improvements with finer-pitch GEMs
K. J. Flöthner, L. Scharenberg, A. Brask +13
Gas Electron Multipliers (GEMs) are used in many particle physics experiments, employing their 'standard' configuration with amplification holes of 140 um pitch in a hexagonal patt…
Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection
J. Schueler, H. M. Araújo, S. N. Balashov +40
Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable…
Performance of the new RD51 VMM3a/SRS beam telescope---studying MPGDs simultaneously in energy, space and time at high rates
L. Scharenberg, J. Bortfeldt, F. Brunbauer +14
The RD51 collaboration maintains a common infrastructure at CERN for its R & D activities, including two beam telescopes for test beam campaigns. Recently, one of the beam telescop…
Demonstration of Gd-GEM detector design for neutron macromolecular crystallography applications
D. Pfeiffer, F. Brunbauer, R. Hall-Wilton +12
The European Spallation Source (ESS) in Lund, Sweden will become the world's most powerful thermal neutron source. The Macromolecular Diffractometer (NMX) at the ESS requires three…