694 citations · 2.3k across the 59 of their papers we have counts for
61 papers
Optical readout of MicroPattern Gaseous Detectors with SiPMs
F. M. Brunbauer, K. J. Flöthner, F. Garcia +13
Scintillation light readout of MicroPattern Gaseous Detectors (MPGDs) is used for imaging and track reconstruction applications including in optical Time Projection Chambers (TPC).…
Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector
Djunes Janssens, Antonija Utrobicic, Marinko Kovacic +52
The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a…
Single channel PICOSEC Micromegas detector with improved time resolution
A. Utrobicic, R. Aleksan, Y. Angelis +47
This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses th…
Characterisation of resistive MPGDs with 2D readout
L. Scharenberg, F. Brunbauer, H. Danielson +22
Micro-Pattern Gaseous Detectors (MPGDs) with resistive anode planes provide intrinsic discharge robustness while maintaining good spatial and time resolutions. Typically read out w…
Signal shapes in multiwire proportional chamber-based TPCs
J. Alme T. Alt H. Appelshäuser M. Arslandok R. Averbeck E. Bartsch P. Becht L. Bratrud P. Braun-Munzinger H. Buesching H. Caines P. Christiansen F. Costa U. Frankenfeld J. J. Gaardhøje C. Garabatos P. Glässel T. Gunji H. Hamagaki J. W. Harris E. Hellbär H. Helstrup M. Ivanov J. Jung M. Jung A. Junique A. Kalweit R. Keidel S. Kirsch M. Kleiner M. Kowalski M. Krüger C. Lippmann M. Mager S. Masciocchi A. Matyja D. Miśkowiec R. H. Munzer L. Musa B. S. Nielsen J. Otwinowski M. Pikna A. Rehman R. Renfordt D. Röhrich H. S. Scheid C. Schmidt H. R. Schmidt K. Schweda Y. Sekiguchi D. Silvermyr B. Sitar J. Stachel K. Ullaland R. Veenhof V. Vislavicius J. Wiechula B. Windelband
A large-volume Time Projection Chamber (TPC) is the main tracking and particle identification (PID) detector of the ALICE experiment at the CERN LHC. PID in the TPC is performed vi…
Studying signals in particle detectors with resistive elements such as the 2D resistive strip bulk MicroMegas
Djunes Janssens, Florian Brunbauer, Karl Jonathan Flöthner +10
As demonstrated by the ATLAS New Small Wheel community with their MicroMegas (MM) design, resistive electrodes are now used in different detector types within the Micro Pattern Gas…
A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution
Antonija Utrobicic, Yannis Angelis, Stephan Aune +42
The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof…
Towards robust PICOSEC Micromegas precise timing detectors
Marta Lisowska, Yannis Angelis, Stephan Aune +43
The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-chann…
The novel XYU-GEM to resolve ambiguities
K. J. Flöthner, F. Brunbauer, S. Ferry +16
Removing ambiguities within a single stage becomes crucial when one can not use multiple detectors behind each other to resolve them which naturally is the case for neutral radiati…
Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes
I. Manthos, S. Aune, J. Bortfeldt +41
Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the…
The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter
H. M. Araújo, S. N. Balashov, J. E. Borg +33
We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron…
Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D
K. Dehmelt, M. Della Pietra, H. Muller +67
This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could…
Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model
C. A. J. O'Hare, D. Loomba, K. Altenmüller +164
Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detecto…
Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System
D. Pfeiffer, L. Scharenberg, P. Schwäbig +20
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (…
Timing performance of a multi-pad PICOSEC-Micromegas detector prototype
S. Aune, J. Bortfeldt, F. Brunbauer +39
The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a…
Nuclear dependence of light neutral meson production in p-A collisions at 400 GeV with NA60
R. Arnaldi, K. Banicz, K. Borer +51
The NA60 experiment has studied low-mass muon pair production in proton-nucleus collisions with a system of Be, Cu, In, W, Pb and U targets, using a 400 GeV proton beam at the CERN…
Optical Readout Studies of the Thick-COBRA Gaseous Detector
F. Garcia, F. M. Brunbauer, M. Lisowska +11
The performance of a Thick-COBRA (THCOBRA) gaseous detector is studied using an optical readout technique. The operation principle of this device is described, highlighting its ope…
Electron transparency of a Micromegas mesh
K. Nikolopoulos, P. Bhattacharya, V. Chernyatin +1
Measurements of the electron transparency of a Micromegas mesh are compared to simulations. The flux conservation argument is shown to lead to inaccurate estimates of the transpare…
Timing Performance of a Micro-Channel-Plate Photomultiplier Tube
Jonathan Bortfeldt, Florian Brunbauer, Claude David +36
The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position informatio…
MPGD simulation in negative-ion gas for direction-sensitive dark matter searches
Hirohisa Ishiura, Rob Veenhof, Kentaro Miuchi +1
Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background r…
Precise Charged Particle Timing with the PICOSEC Detector
J. Bortfeldt, F. Brunbauer, C. David +38
The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabili…
Modeling the Timing Characteristics of the PICOSEC Micromegas Detector
J. Bortfeldt, F. Brunbauer, C. David +38
The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also dem…
Interfacing Geant4, Garfield++ and Degrad for the Simulation of Gaseous Detectors
Dorothea Pfeiffer, Lennert De Keukeleere, Carlos Azevedo +10
For several years, attempts have been made to interface Geant4 and other software packages with the aim of simulating the complete response of a gaseous particle detector. In such…
Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept
F. J. Iguaz, J. Bortfeldt, F. Brunbauer +38
The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been te…