3k citations · 6.6k across the 47 of their papers we have counts for
13 papers · 1 filter
COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils
D. Akimov, P. An, C. Awe +75
Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHER…
Monitoring the SNS basement neutron background with the MARS detector
COHERENT Collaboration, D. Akimov, P. An +75
We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for…
Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT
D. Akimov, P. An, C. Awe +74
We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic…
Optical calibration of the SNO+ detector in the water phase with deployed sources
SNO+ Collaboration, :, M. R. Anderson +120
SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB,…
The SNO+ Experiment
SNO+ Collaboration, :, V. Albanese +251
The SNO+ experiment is located 2 km underground at SNOLAB in Sudbury, Canada. A low background search for neutrinoless double beta () decay will be conducted using 780 tonnes…
A DO detector for flux normalization of a pion decay-at-rest neutrino source
COHERENT Collaboration, D. Akimov, P. An +76
We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino sou…
Development, characterisation, and deployment of the SNO+ liquid scintillator
SNO+ Collaboration, :, M. R. Anderson +223
A liquid scintillator consisting of linear alkylbenzene as the solvent and 2,5-diphenyloxazole as the fluor was developed for the SNO+ experiment. This mixture was chosen as it is…
Development of a Kr source for the calibration of the CENNS-10 Liquid Argon Detector
COHERENT Collaboration, D. Akimov, P. An +77
We report on the preparation of and calibration measurements with a Kr source for the CENNS-10 liquid argon detector. Kr atoms generated in the de…
COHERENT 2018 at the Spallation Neutron Source
D. Akimov, J. B. Albert, P. An +76
The primary goal of the COHERENT collaboration is to measure and study coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power, few-tens-of-MeV, pulsed source of…
Current Status and Future Prospects of the SNO+ Experiment
SNO+ Collaboration, :, S. Andringa +155
SNO+ is a large liquid scintillator-based experiment located 2km underground at SNOLAB, Sudbury, Canada. It reuses the Sudbury Neutrino Observatory detector, consisting of a 12m di…
Systematic study of trace radioactive impurities in candidate construction materials for EXO-200
D. S. Leonard, P. Grinberg, P. Weber +54
The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a…
A linear RFQ ion trap for the Enriched Xenon Observatory
B. Flatt, M. Green, J. Wodin +39
The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the…
A liquid xenon ionization chamber in an all-fluoropolymer vessel
EXO Collaboration, F. LePort, A. Pocar +42
A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low ra…