10.1k citations · 25.9k across the 411 of their papers we have counts for
10 papers · 1 filter
Study of Particle Fluence Effects on Collected Charge and Depletion Voltage of the ATLAS IBL Planar Pixel Sensors
ATLAS Collaboration
After ten years of operation at the LHC, the planar pixel sensors of the innermost barrel layer of the ATLAS Pixel detector have accumulated an average bulk damage fluence in exces…
Sensor response and radiation damage effects for 3D pixels in the ATLAS IBL Detector
ATLAS Collaboration
Pixel sensors in 3D technology equip the outer ends of the staves of the Insertable B Layer (IBL), the innermost layer of the ATLAS Pixel Detector, which was installed before the s…
Beam-induced backgrounds measured in the ATLAS detector during local gas injection into the LHC beam vacuum
ATLAS Collaboration
Inelastic beam-gas collisions at the Large Hadron Collider (LHC), within a few hundred metres of the ATLAS experiment, are known to give the dominant contribution to beam backgroun…
Performance of the ATLAS forward proton Time-of-Flight detector in Run 2
ATLAS Collaboration
We present performance studies of the Time-of-Flight (ToF) subdetector of the ATLAS Forward Proton (AFP) detector at the LHC. Efficiencies and resolutions are measured using high-s…
Improving topological cluster reconstruction using calorimeter cell timing in ATLAS
ATLAS Collaboration
Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal reconstruction in…
The ATLAS Experiment at the CERN Large Hadron Collider: A Description of the Detector Configuration for Run 3
ATLAS Collaboration
The ATLAS detector is installed in its experimental cavern at Point 1 of the CERN Large Hadron Collider. During Run 2 of the LHC, a luminosity of $\mathcal{L}=2\times 10^{34}\mathr…
Measurements with silicon photomultipliers of dose-rate effects in the radiation damage of plastic scintillator tiles in the CMS hadron endcap calorimeter
CMS Collaboration
Measurements are presented of the reduction of signal output due to radiation damage for plastic scintillator tiles used in the hadron endcap (HE) calorimeter of the CMS detector.…
Performance of the reconstruction and identification of high-momentum muons in proton-proton collisions at 13 TeV
CMS Collaboration
The CMS detector at the LHC has recorded events from proton-proton collisions, with muon momenta reaching up to 1.8 TeV in the collected dimuon samples. These high-momentum muons a…
Particle-flow reconstruction and global event description with the CMS detector
CMS Collaboration
The CMS apparatus was identified, a few years before the start of the LHC operation at CERN, to feature properties well suited to particle-flow (PF) reconstruction: a highly-segmen…
The CMS trigger system
CMS Collaboration
This paper describes the CMS trigger system and its performance during Run 1 of the LHC. The trigger system consists of two levels designed to select events of potential physics in…