activity
20162026
most citedDose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter

25 citations · 94 across the 11 of their papers we have counts for

collaborators

12 papers

physics.ins-det2026

Cherenkov and scintillation light separation in BGO and BSO crystals coupled to SiPMs for dual-readout electromagnetic calorimetry at future colliders

M. Alviggi, B. Argiento, E. Auffray +29

We report on the separation of Cherenkov and scintillation light in BGO and BSO crystals read out with silicon photomultipliers (SiPMs). The two light components are disentangled o…

physics.ins-det2025★ 1 cited

Characterization of thin optical filters for high purity Cherenkov light readout from scintillating crystals

Andrea Benaglia, Flavia Cetorelli, Marco Toliman Lucchini +3

A hybrid dual-readout calorimeter concept, comprising both electromagnetic and hadronic sections, has recently been proposed to meet the performance requirements of experiments at…

physics.acc-ph2025

Future Circular Collider Feasibility Study Report: Volume 2, Accelerators, Technical Infrastructure and Safety

M. Benedikt, F. Zimmermann, B. Auchmann +1461

In response to the 2020 Update of the European Strategy for Particle Physics, the Future Circular Collider (FCC) Feasibility Study was launched as an international collaboration ho…

physics.acc-ph2025★ 3 cited

Future Circular Collider Feasibility Study Report: Volume 3, Civil Engineering, Implementation and Sustainability

M. Benedikt, F. Zimmermann, B. Auchmann +1461

Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability asp…

hep-ex2025★ 24 cited

Future Circular Collider Feasibility Study Report: Volume 1, Physics, Experiments, Detectors

M. Benedikt, F. Zimmermann, B. Auchmann +1461

Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume o…

physics.ins-det2025★ 9 cited

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

F. Addesa, P. Akrap, A. Albert +127

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedent…

physics.ins-det2024

Optimization of LYSO crystals and SiPM parameters for the CMS MIP timing detector

F. Addesa, T. Anderson, P. Barria +68

For the High-Luminosity (HL-LHC) phase, the upgrade of the Compact Muon Solenoid (CMS) experiment at CERN will include a novel MIP Timing Detector (MTD). The central part of MTD, t…

physics.ins-det2024

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

E. Albuquerque, M. Araújo, A. Benaglia +38

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providin…

physics.ins-det2023★ 15 cited

Integration of thermo-electric coolers into the CMS MTD SiPM arrays for operation under high neutron fluence

A. Bornheim, W. Lustermann, K. Stachon +27

The barrel section of the novel MIP Timing Detector (MTD) will be constructed as part of the upgrade of the CMS experiment to provide a time resolution for single charged tracks in…

physics.ins-det2022★ 3 cited

Sub-10 ps time tagging of electromagnetic showers with scintillating glasses and SiPMs

Marco T. Lucchini, Andrea Benaglia, Stefan Gundacker +6

The high energy physics community has recently identified an Higgs factory as one of the next-generation collider experiments, following the completion of the High Luminos…

physics.ins-det2021★ 14 cited

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

R. Abbott, A. Abreu, F. Addesa +196

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event re…

physics.ins-det2016★ 25 cited

Dose rate effects in the radiation damage of the plastic scintillators of the CMS Hadron Endcap Calorimeter

HCAL collaboration

We present measurements of the reduction of light output by plastic scintillators irradiated in the CMS detector during the 8 TeV run of the Large Hadron Collider and show that the…