activity
20162026
most citedSystematic Uncertainties in RF-Based Measurement of Superconducting Cavity Quality Factors

9 citations · 21 across the 11 of their papers we have counts for

collaborators

11 papers

physics.acc-ph2026

Heat load measurements for the PIP-II pHB650 cryomodule

D. Porwisiak, M. J. White, V. Roger +11

Phase-3 testing of the pHB650 cryomodule at the PIP-II Injector Test Facility was conducted to evaluate the effectiveness of heat load mitigations performed after earlier phases of…

physics.acc-ph2024

Performance of PIP-II High-beta 650 Cryomodule After Transatlantic Shipping

J. Ozelis, M. Barba, J. Bernardini +27

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may hav…

physics.acc-ph2023

Installation, commissioning, and testing of the HB650 CM at PIP2IT

M White, J Makara, S Ranpariya +10

The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LI…

physics.acc-ph2023

The Evaluation of Mechanical Properties of LB650 Cavities

J. Holzbauer, G. Wu, H. Park +13

The PIP-II project's LB650 cavities could potentially be vulnerable to mechanical deformation because of the geometric shape of the cavity due to reduced beta. The mechanical prope…

physics.acc-ph2023

Transportation Fatigue Testing of the pHB650 Power Coupler Antenna for the PIP-II Project at Fermilab

J. Helsper, S. Chandrasekaran, J. Holzbauer +1

The PIP-II Project will see international shipment of cryomodules from Europe to the United States, and as such, the shocks which can occur during shipment pose a risk to the inter…

physics.acc-ph2022

LCLS-II and HE Cryomodule Microphonics at CMTF in Fermilab*

C. Contreras-Martinez, E. Harms, C. Cravatta +7

Microphonics causes the cavity to detune. This study discusses the microphonics of sixteen 1.3 GHz cryomodules, 14 for LCLS-II and 2 for LCLS-II HE tested at CMTF. The peak detunin…

physics.acc-ph2021★ 1 cited

LCLS-II-HE verification cryomodule high gradient performance and quench behavior

S. Posen, A. Cravatta, M. Checchin +43

An 8-cavity, 1.3 GHz, LCLS-II-HE cryomodule was assembled and tested at Fermilab to verify performance before the start of production. Its cavities were processed with a novel nitr…

physics.acc-ph2018★ 2 cited

Commissioning And First Results From The Fermilab Cryomodule Test Stand

E. R. Harms, M. Awida, C. Baffes +34

A new test stand dedicated to Superconducting Radiofrequency (SRF) cryomodule testing, CMTS1, has been commissioned and is now in operation at Fermilab. The first device to be cool…

physics.acc-ph2018★ 9 cited

Improved RF Measurements of SRF Cavity Quality Factors

J. P. Holzbauer, C. Contreras, Y. Pischalnikov +2

SRF cavity quality factors can be accurately measured using RF-power based techniques only when the cavity is very close to critically coupled. This limitation is from systematic e…

physics.acc-ph2018

Low Level RF Control for the PIP-II Accelerator

J. P. Edelen, B. E. Chase, E. Cullerton +9

The PIP-II accelerator is a proposed upgrade to the Fermilab accelerator complex that will replace the existing, 400 MeV room temperature LINAC with an 800 MeV superconducting LINA…

physics.acc-ph2016★ 9 cited

Systematic Uncertainties in RF-Based Measurement of Superconducting Cavity Quality Factors

J. P. Holzbauer, Yu. Pischalnikov, D. A. Sergatskov +2

Q0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Instrumental factors…