activity
20092021
most citedBiological measurement beyond the quantum limit

575 citations · 1.5k across the 17 of their papers we have counts for

collaborators

17 papers

quant-ph2021

Quantum Enhanced Microrheology of a Living Cell

Michael A. Taylor, Jiri Janousek, Vincent Daria +4

We demonstrate the first biological measurement with precision surpassing the quantum noise limit. Lipid particles within a living yeast cell are tracked with sub-shot noise sensit…

physics.optics2021★ 135 cited

Ultrasensitive optical magnetometry at the microscale

Stefan Forstner, Eoin Sheridan, Joachim Knittel +4

Recent advances in optical magnetometry have achieved record sensitivity at both macro- and nano-scale. Combined with high bandwidth and non-cryogenic operation, this has enabled m…

physics.optics2013★ 15 cited

Tapered nanofiber trapping of high-refractive-index nanoparticles

Jon D. Swaim, Joachim Knittel, Warwick P. Bowen

A nanofiber-based optical tweezer is demonstrated. Trapping is achieved by combining attractive near-field optical gradient forces with repulsive electrostatic forces. Silica-coate…

physics.optics2013

Back-scatter based whispering gallery mode sensing

Joachim Knittel, Jon D. Swaim, David L. McAuslan +2

Whispering gallery mode biosensors allow selective unlabelled detection of single proteins and, combined with quantum limited sensitivity, the possibility for noninvasive realtime…

physics.optics2013★ 67 cited

Subdiffraction-limited quantum imaging within a living cell

Michael A. Taylor, Jiri Janousek, Vincent Daria +4

We report both sub-diffraction-limited quantum metrology and quantum enhanced spatial resolution for the first time in a biological context. Nanoparticles are tracked with quantum…

physics.optics2013★ 112 cited

Detection of Nanoparticles with a Frequency Locked Whispering Gallery Mode Microresonator

Jon D. Swaim, Joachim Knittel, Warwick P. Bowen

We detect 39 nm x 10 nm gold nanorods using a microtoroid stabilized via the Pound-Drever-Hall method. Real-time detection is achieved with signal-to-noise ratios up to 12.2. These…

physics.optics2013★ 15 cited

Optical lock-in particle tracking in optical tweezers

Michael A Taylor, Joachim Knittel, Warwick P Bowen

We demonstrate a lock-in particle tracking scheme in optical tweezers based on stroboscopic modulation of an illuminating optical field. This scheme is found to evade low frequency…

physics.optics2012★ 30 cited

Fundamental constraints on particle tracking with optical tweezers

Michael A. Taylor, Joachim Knittel, Warwick P. Bowen

A general quantum limit to the sensitivity of particle position measurements is derived following the simple principle of the Heisenberg microscope. The value of this limit is calc…

quant-ph2012★ 575 cited

Biological measurement beyond the quantum limit

Michael A. Taylor, Jiri Janousek, Vincent Daria +4

Quantum noise places a fundamental limit on the per photon sensitivity attainable in optical measurements. This limit is of particular importance in biological measurements, where…

physics.optics2011★ 303 cited

Cavity Optomechanical Magnetometer

S. Forstner, S. Prams, J. Knittel +6

A cavity optomechanical magnetometer is demonstrated where the magnetic field induced expansion of a magnetostrictive material is transduced onto the physical structure of a highly…

quant-ph2011★ 26 cited

Feedback Enhanced Sensitivity in Optomechanics: Surpassing the Parametric Instability Barrier

Glen I. Harris, Ulrik L. Andersen, Joachim Knittel +1

The intracavity power, and hence sensitivity, of optomechanical sensors is commonly limited by parametric instability. Here we characterize the parametric instability induced sensi…

physics.ins-det2011★ 15 cited

Cavity optoelectromechanical regenerative amplification

Michael A. Taylor, Alex Szorkovszky, Joachim Knittel +3

Cavity optoelectromechanical regenerative amplification is demonstrated. An optical cavity enhances mechanical transduction, allowing sensitive measurement even for heavy oscillato…

physics.optics2011★ 1 cited

Detection limits in plasmonic whispering gallery mode biosensors

Jon D. Swaim, Joachim Knittel, Warwick P. Bowen

We analyze a whispering gallery mode biosensor with a metallic nanorod bound to its surface. It is found that a localized surface plasmon resonance in the nanorod can reduce the op…

physics.optics2010★ 4 cited

Yield enhancement in whispering gallery mode biosensors: microfluidics and optical forces

Kiran Khosla, Jon D. Swaim, Joachim Knittel +1

A microfluidic whispering gallery mode (WGM) biosensing system is proposed for enhanced delivery and detection of target molecules. A microtoroid resonator coupled to a tapered opt…

physics.optics2010★ 49 cited

Interferometric detection of mode splitting for whispering gallery mode biosensors

Joachim Knittel, Terry G. McRae, Kwan H. Lee +1

Sensors based on whispering gallery mode resonators can detect single nanoparticles and even single molecules. Particles attaching to the resonator induce a doublet in the transmis…

quant-ph2010★ 20 cited

Cavity opto-electromechanical system combining strong electrical actuation with ultrasensitive transduction

Terry G. McRae, Kwan H. Lee, Glen I. Harris +2

A cavity opto-electromechanical system is reported which combines the ultrasensitive transduction of cavity optomechanical systems with the electrical actuation of nanoelectromecha…

quant-ph2009★ 111 cited

Cooling and control of a cavity opto-electromechanical system

Kwan H. Lee, Terry G. McRae, Glen I. Harris +2

We implement a cavity opto-electromechanical system integrating electrical actuation capabilities of nanoelectromechanical devices with ultrasensitive mechanical transduction achie…